// CODE SNIPPET
M2301.7.2 Direct Systems
JUMP TO FULL CODE CHAPTER
Where potable water is directly heated by a solar thermal system, the pipe, fittings, valves and other components that are in contact with the potable water in the solar heating system shall comply with the requirements of Chapter 29.
Related Code Sections
M2301.7.2 Solar Thermal Energy Systems, Direct Systems
Where potable water is directly heated by a solar thermal system, the pipe, fittings, valves and other components that are in contact ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 23 Solar Thermal Energy Systems > M2301 Thermal Solar Energy Systems > M2301.7 Solar Thermal Systems for Heating Potable Water > M2301.7.2 Direct Systems
P2902.5.5.2 Water Supply and Distribution, Direct Systems for Potable Water Distribution Systems
Where a solar thermal system directly heats potable water for a potable water distribution system, the pipe, fittings, valves and other components ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.5 Protection of Potable Water Connections > P2902.5.5 Solar Thermal Systems > P2902.5.5.2 Direct Systems for Potable Water Distribution Systems
1103.3.2 Refrigeration, High-Probability Systems
Direct systems and indirect open-spray systems shall be classified as highprobability systems.
Exception: An indirect open-spray system shall ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 11 Refrigeration > 1103 Refrigeration System Classification > 1103.3 System Classification > 1103.3.2 High-Probability Systems
M1411.1 Heating and Cooling Equipment and Appliances, Approved Refrigerants
Refrigerants used in direct refrigerating systems shall conform to the applicable provisions of ANSI/ASHRAE 34 ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 14 Heating and Cooling Equipment and Appliances > M1411 Heating and Cooling Equipment > M1411.1 Approved Refrigerants
1107.2.2 Refrigeration, Refrigerant Penetrations
system.
Penetrations by piping in a direct system where the refrigerant quantity does not exceed Table 1103.1 for the smallest occupied space ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 11 Refrigeration > 1107 Refrigerant Piping > 1107.2 Piping Location > 1107.2.2 Refrigerant Penetrations