1910.263(l)(10) Direct-Fired Ovens
JUMP TO FULL CODE CHAPTER
Direct-fired ovens shall be afeguarded against failure of fuel, air, or ignition.
To prevent the possible accumulation of explosive gases from being ignited after a shutdown, all direct-fired ovens with a heating capacity over 150,000 B.t.u. per hour shall be ventilated before the ignition system, combustion air blower, and the fuel can be turned on. The preventilation shall insure at least four complete changes of atmosphere in the baking chamber by discharging the oven atmosphere to the outside of the building and entraining fresh air into it. The preventilation shall be repeated whenever the heating equipment is shut down by a safety device.
Related Code Sections
1910.263(l)(10) Special Industries, Direct-Fired Ovens
Direct-fired ovens shall be afeguarded against failure of fuel, air, or ignition ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens > 1910.263(l)(10) Direct-Fired Ovens
1910.263 Special Industries, Bakery Equipment
Any space in an oven (except direct fired ovens) which could be filled with an explosive ...
1910.263(l)(11) Special Industries, Direct Recirculating Ovens
Each circulating fan in direct recirculating ovens shall be interconnected with the burner in such a manner that the fuel is shut off by a safety ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens > 1910.263(l)(11) Direct Recirculating Ovens
1910.263(l)(11)(i) Special Industries,
Each circulating fan in direct recirculating ovens shall be interconnected with the burner in such a manner that the fuel is shut off by a safety ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens > 1910.263(l)(11) Direct Recirculating Ovens > 1910.263(l)(11)(i)
1910.263(l)(11)(ii) Special Industries,
The flame of the burner or burners in direct recirculating ovens shall be protected by a quick-acting flame-sensitive safeguard which ...
OSHA 1910 General Industry > R Special Industries > 1910.263 Bakery Equipment > 1910.263(l) Ovens > 1910.263(l)(11) Direct Recirculating Ovens > 1910.263(l)(11)(ii)