• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1809.3.4 Dimensions of Steel Pipe Piles

2010 Building Code of NY > 18 Soils and Foundations > 1809 Driven Pile Foundations > 1809.3 Structural Steel Piles > 1809.3.4 Dimensions of Steel Pipe Piles
JUMP TO FULL CODE CHAPTER
Steel pipe piles driven open ended shall have a nominal outside diameter of not less than 8 inches (203 mm). The pipe shall have a minimum cross section of 0.34 square inch (219 mm2) to resist each 1,000 foot-pounds (1356 N-m) of pile hammer energy, or shall have the equivalent strength for steels having a yield strength greater than 35,000 psi (241 Mpa) or the wave equation analysis shall be permitted to be used to assess compression stresses induced by driving to evaluate if the pile section is appropriate for the selected hammer. Where pipe wall thickness less than 0.179 inch (4.6 mm) is driven open ended, a suitable cutting shoe shall be provided.

Related Code Sections


1809.3.4 Soils and Foundations, Dimensions of Steel Pipe Piles
Steel pipe piles driven open ended shall have a nominal outside diameter of not less than 8 inches (203 mm). The pipe shall have a minimum cross ...
2010 Building Code of NY > 18 Soils and Foundations > 1809 Driven Pile Foundations > 1809.3 Structural Steel Piles > 1809.3.4 Dimensions of Steel Pipe Piles
1810.3.5.3 Soils and Foundations, Steel
Sections of structural steel H-piles shall comply with the requirements for HP shapes in ASTM A6, or the following ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.3 Design and Detailing > 1810.3.5 Dimensions of Deep Foundation Elements > 1810.3.5.3 Steel
1810.3.5.3 Soils and Foundations, Steel
Sections of structural steel H-piles shall comply with the requirements for HP shapes in ASTM A6, or the following ...
2020 Building Code of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.3 Design and Detailing > 1810.3.5 Dimensions of Deep Foundation Elements > 1810.3.5.3 Steel
1808.1 Soils and Foundations, Definitions
-inch-diameter (305 mm) or less bored, grouted-in-place piles incorporating steel pipe (casing) and/or steel reinforcement. PIER FOUNDATIONS. Pier ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.1 Definitions
1810.6.3 Soils and Foundations, Minimum Dimensions
mandrel-driven pipe piles, the minimum wall thickness shall be 1 / 10 inch (2.5 mm) ...
2010 Building Code of NY > 18 Soils and Foundations > 1810 Cast-In-Place Concrete Pile Foundations > 1810.6 Concrete-Filled Steel Pipe and Tube Piles > 1810.6.3 Minimum Dimensions
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE