3308.7.3 Dimensions and Materials
JUMP TO FULL CODE CHAPTER
Toprails, midrails, toeboards, and posts shall have the following dimensions and be constructed out of the following materials:
- Toprails shall, at a minimum, consist of:
- 2 inch by 4 inch (51 mm by 102 mm) 1500 foot pounds per square inch (1.05 kgf/mm2) fiber (stress grade) construction grade lumber;
- 11/2 inch (38 mm) nominal diameter (Schedule 40) pipe;
- 2 inch by 2 inch by 3/8 inch (51 x 51 x 10 mm) structural angle; or
- 1/4 inch (6 mm) diameter noncorrosive wire cable made of mild plow steel.
- Midrails shall, at a minimum, consist of:
- 1 inch by 6 inch (25 mm by 152 mm) 1500 lb-ft/in2 (1.05 kgf/mm2) fiber (stress grade) construction grade lumber;
- 11/2 inch (38 mm) nominal diameter (schedule 40) pipe;
- 2 inch by 2 inch by 3/8 inch (51 x 51 x 10 mm) structural angle; or
- 1/4 inch (6 mm) diameter noncorrosive wire cable made of mild plow steel.
- Toeboards shall, at a minimum, consist of:
- 1 inch by 6 inch (25 mm by 152 mm) lumber; or
- Metal plank at least 31/2 inches (89 mm) high.
- Toprails, midrails, and toeboards shall be securely fastened to upright posts spaced not more than 8 feet (2438 mm) apart. Such posts shall, at a minimum, consist of:
- 2 inch by 4 inch (51 mm by 102 mm) 1500 foot pounds per square inch (1.05 kgf/mm2) fiber (stress grade) construction grade lumber;
- 11/2 inch (38 mm) nominal diameter (schedule 40) pipe;
- 2 inch by 2 inch by 3/8 inch (51 x 51 x 10 mm) structural angle; or
- A building column.
Exceptions:
- Guardrail systems designed by a registered design professional capable of withstanding, without failure:
- A force of at least 200 pounds (890 n) applied within 2 inches (51 mm) of the top edge, in any outward or downward direction, at any point along the top edge. Where the force is applied in a downward direction, the top edge shall not deflect more than 6 inches (152 mm) and in no case to a height less than 39 inches (991 mm) above the floor; and
- A load of at least 50 pounds (222 n) applied in any downward or horizontal direction at any point along the toeboard.
- Posts supporting wire cable toprails and midrails, as well as the toeboards utilized in connection with such wire cable toprails and midrails, may be spaced more than 8 feet (2438 mm) apart provided that the posts are spaced such that where a force of 200 pounds (890 n) is applied in a downward direction along the top edge, the top edge shall not deflect more than 6 inches (152 mm) and in no case to a height less than 39 inches (991 mm) above the floor.
Related Code Sections
3308.7.3 Safeguards During Construction or Demolition, Dimensions and Materials
Toprails, midrails, toeboards, and posts shall have the following dimensions and be constructed out of the following materials:
Toprails shall ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.7 Guardrail System > 3308.7.3 Dimensions and Materials
Section 1201 Interior Environment, General
The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions ...
Section 1201 Interior Environment, General
The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions ...
2508.5.3 Gypsum Board and Plaster, Blocking of Perimeter Edges
All perimeter edges shall be blocked using a wood member not less than 2-inch by 6-inch (51 mm by 152 mm) nominal dimension. Blocking material shall ...
NYC Building Code 2008 > 25 Gypsum Board and Plaster > 2508 Gypsum Construction > 2508.5 Horizontal Gypsum Board Diaphragm Ceilings > 2508.5.3 Blocking of Perimeter Edges
2508.5.3 Gypsum Board and Plaster, Blocking of Perimeter Edges
All perimeter edges shall be blocked using a wood member not less than 2-inch by 6-inch (51 mm by 152 mm) nominal dimension. Blocking material shall ...
NYC Building Code 2014 > 25 Gypsum Board and Plaster > 2508 Gypsum Construction > 2508.5 Horizontal Gypsum Board Diaphragm Ceilings > 2508.5.3 Blocking of Perimeter Edges