505.13 Different Piping Materials
JUMP TO FULL CODE CHAPTER
Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM C 1173, ASTM C 1460 or ASTM C 1461. Connectors or adapters shall be approved for the application and such joints shall have an elastomeric seal conforming to ASTM C 425, ASTM C 443, ASTM C 564, ASTM C 1440, ASTM D 1869, ASTM F 477, CSA A257.3M or CSA B602 or as required in Sections 505.13.1 and 505.13.2. Joints shall be installed in accordance with the manufacturer's instructions.
Joints between copper or copper-alloy tubing and cast-iron hub pipe shall be made with a brass ferrule or compression joint. The copper or copper-alloy tubing shall be soldered to the ferrule in an approved manner, and the ferrule shall be joined to the cast-iron hub by a caulked joint or a mechanical compression joint.
Joints between different grades of plastic pipe or between plastic pipe and other piping material shall be made with an approved adapter fitting. Joints between plastic pipe and cast-iron hub pipe shall be made by a caulked joint or a mechanical compression joint.
Related Code Sections
505.13 Materials, Different Piping Materials
Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM ...
Private Sewage Disposal Code 2018 > 5 Materials > 505 Pipe, Joints and Connections > 505.13 Different Piping Materials
505.13 Materials, Different Piping Materials
Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM C ...
Private Sewage Disposal Code 2009 > 5 Materials > 505 Pipe, Joints and Connections > 505.13 Different Piping Materials
505.13 Materials, Different Piping Materials
Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM C ...
Private Sewage Disposal Code 2012 > 5 Materials > 505 Pipe, Joints and Connections > 505.13 Different Piping Materials
505.13 Materials, Different Piping Materials
Joints between different piping materials shall be made with a mechanical joint of the compression or mechanical-sealing type conforming to ASTM C ...
Private Sewage Disposal Code 2015 > 5 Materials > 505 Pipe, Joints and Connections > 505.13 Different Piping Materials
1210.6.1 Hydronic Piping, Joints Between Different Piping Materials
Joints between different piping materials shall be made with approved transition fittings ...
Mechanical Code 2015 > 12 Hydronic Piping > 1210 Plastic Pipe Ground-Source Heat Pump Loop Systems > 1210.6 Joints > 1210.6.1 Joints Between Different Piping Materials