1926.756(b) Diagonal Bracing
JUMP TO FULL CODE CHAPTER
Solid web structural members used as diagonal bracing shall be secured by at least one bolt per connection drawn up wrench-tight or the equivalent as specified by the project structural engineer of record.
Related Code Sections
1926.756(b) Steel Erection, Diagonal Bracing
Solid web structural members used as diagonal bracing shall be secured by at least one bolt per connection drawn up wrench-tight or the equivalent ...
OSHA 1926 Construction > R Steel Erection > 1926.756 Beams and Columns > 1926.756(b) Diagonal Bracing
1926.452(e) Scaffolds, Bricklayers' Square Scaffolds (Squares)
Diagonal braces shall be installed on all sides of each square ...
OSHA 1926 Construction > L Scaffolds > 1926.452 Additional Requirements Applicable to Specific Types of Scaffolds > 1926.452(e) Bricklayers' Square Scaffolds (Squares)
1926.703(b)(8)(iv) Concrete and Masonry Construction,
The single post shores shall be a adequately braced in two mutually perpendicular directions at the splice level. Each tier shall also be diagonally ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(b) Shoring and Reshoring > 1926.703(b)(8) > 1926.703(b)(8)(iv)
1926.452(w)(1) Scaffolds,
Scaffolds shall be braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold ...
OSHA 1926 Construction > L Scaffolds > 1926.452 Additional Requirements Applicable to Specific Types of Scaffolds > 1926.452(w) Mobile Scaffolds > 1926.452(w)(1)
1926.703(b)(8) Concrete and Masonry Construction,
be a adequately braced in two mutually perpendicular directions at the splice level. Each tier shall also be diagonally braced in the same two directions ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.703 Requirements for Cast-In-Place Concrete > 1926.703(b) Shoring and Reshoring > 1926.703(b)(8)