• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

465.5.2.1.4.3 Devices Shall Be Utilized Which Will:

2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 465 Control of Radiation Hazards > 465.5 General Requirements > 465.5.2 X-Ray Film Processing Facilities > 465.5.2.1 Processing Facilities > 465.5.2.1.4 > 465.5.2.1.4.3 Devices Shall Be Utilized Which Will:
JUMP TO FULL CODE CHAPTER
  1. Indicate the actual temperature of the developer; and
  2. Signal the passage of a preset time as short as 2 minutes.

Related Code Sections


465.5.2.1.4.3 Special Detailed Requirements Based on Use and Occupancy, Devices Shall Be Utilized Which Will:
Indicate the actual temperature of the developer; and Signal the passage of a preset time as short as 2 minutes ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 465 Control of Radiation Hazards > 465.5 General Requirements > 465.5.2 X-Ray Film Processing Facilities > 465.5.2.1 Processing Facilities > 465.5.2.1.4 > 465.5.2.1.4.3 Devices Shall Be Utilized Which Will:
E3705.7 Branch Circuit and Feeder Requirements, Location of Overcurrent Devices in or on Premises
Overcurrent devices shall: Be readily accessible. Not be located where they will be exposed to physical damage. Not be located where ...
2014 FBC - Residential, 5th edition > 37 Branch Circuit and Feeder Requirements > E3705 Conductor Sizing and Overcurrent Protection > E3705.7 Location of Overcurrent Devices in or on Premises
E3705.7 Branch Circuit and Feeder Requirements, Location of Overcurrent Devices in or on Premises
Overcurrent devices shall: Be readily accessible. [240.24(A)] Not be located where they will be exposed to physical damage. [240.24(C)] Not ...
2017 FBC - Residential, 6th edition > 37 Branch Circuit and Feeder Requirements > E3705 Conductor Sizing and Overcurrent Protection > E3705.7 Location of Overcurrent Devices in or on Premises
R403.2.4 [RE] Residential Energy Efficiency, Air-Handling Units
OF THE FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR (2) A DEVICE THAT WILL SHUT THE SYSTEM DOWN ...
2014 FBC - Energy Conservation, 5th edition > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.2 Ducts > R403.2.4 Air-Handling Units
R403.3.6 [RE] Residential Energy Efficiency, Air-Handling Units
FOLLOWING: (1) A DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION DRAIN IS NOT WORKING PROPERLY OR (2) A DEVICE THAT WILL SHUT DOWN THE SYSTEM WHEN ...
2017 FBC - Energy Conservation, 6th edition > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.3 Ducts > R403.3.6 Air-Handling Units
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE