• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

74-68 Development Within or Over a Right-Of-Way or Yards

NYC Zoning Resolution > VII Administration > 4 - Special Permits by the City Planning Commission > 74-60 Public Service or Transportation Facilities > 74-68 Development Within or Over a Right-Of-Way or Yards
JUMP TO FULL CODE CHAPTER

74-681 Development Within or Over a Railroad or Transit Right-Of-Way or Yard

(a)        In all districts, when a development or enlargement, including large-scale developments pursuant to Section 74-74, 78-00 et seq. or 79-00 et seq. is located partially or entirely within a railroad or transit right-of-way or yard and/or in railroad or transit air space, the City Planning Commission may permit:

(1)        that portion of the railroad or transit right-of-way or yard which will be completely covered over by a permanent platform to be included in the lot area for such development or enlargement;

(2)        any portion of the right-of-way or yard where railroad or transit use has been permanently discontinued or terminated to be included in the lot area for such development or enlargement;

(3)        notwithstanding the applicable district regulations, certain uses may be located beneath a portion of a permanent platform, including a platform street as follows:

(i)        any use accessory to a primary use located on the zoning lot;

(ii)        a public parking garage or public parking lot provided the findings set forth in Section 74-52 and hereby made applicable, are met for such garage or lot;

(iii)        a railroad passenger station (pursuant to Section 74-62) or a railroad including right-of-way, freight terminal, yard or appurtenance, or a facility or service used or required in railroad operations;

(iv)        a public transit yard, vehicle storage, warehouse, trucking terminal or motor freight station (without limitation on lot area per establishment).

(b)        As a condition for granting a special permit, the Commission shall find that:

(1)        the streets providing access to all uses pursuant to paragraph (a) of this Section are adequate to handle traffic resulting therefrom;

(2)        the distribution of floor area and the number of dwelling units or rooming units does not adversely affect the character of the surrounding area by being unduly concentrated in any portion of such development or enlargement, including any portion of the development or enlargement located beyond the boundaries of such railroad or transit right-of-way or yard;

(3)        all uses, developments or enlargements located on the zoning lot or below a platform do not adversely affect one another;

(4)        if such railroad or transit right-of-way or yard is deemed appropriate for future transportation use, the site plan and structural design of the development do not preclude future use of, or improvements to, the right-of-way for such transportation use.

(c)        For any development or enlargement located within or over railroad or transit right-of-way or yard:

(1)        the application to be filed with the Commission for special permit approval pursuant to this Section shall include a site plan showing:

(i)        the total lot area of that portion of a railroad or transit right-of-way or yard to be covered by a platform; and/or

(ii)        the total lot area of such right-of-way or yard that has been permanently discontinued or terminated;

(2)        ownership of rights to develop in railroad or transit air space or within a railroad or transit right-of-way or yard where such use has been permanently discontinued or terminated, shall meet the requirements of the zoning lot definition in Section 12-10 (DEFINITIONS);

(3)        where the railroad or transit right-of-way or yard is to be covered over by a permanent platform, such platform shall be unperforated except for such suitably protected openings as may be required for utilities, ventilation, drainage or other necessary purposes;

(4)        the Commission may establish an appropriate level or levels instead of curb level as the reference plane for the applicable regulations pertaining to, but not limited to, height and setback, floor area, lot coverage, open space, yards, and minimum distance between buildings;

(5)        the Commission may permit buildings to be connected by a bridge or tunnel, within a portion of a street, provided that the street volume occupied by such bridge or tunnel is not mapped and owned by the City, and provided that such structure is used exclusively for pedestrian or vehicular circulation; however, in no event shall such a bridge or tunnel be considered as lot area or generate any floor area; and in the case of a bridge, the Commission shall find that such bridge will:

(i)        provide adequate vertical clearance at all points measured from curb level to the soffit;

(ii)        not rest upon columns or other supports that intrude upon the street;

(iii)        provide illumination of at least five foot candles at the curb level for the street area beneath the bridge;

(iv)        not unduly obstruct any significant scenic view; and

(v)        provide adequate light and air to the street or surrounding public spaces or streets.

In the case of a tunnel, the Commission may permit buildings to be connected by a tunnel under a street, provided the Commission finds that the tunnel is used exclusively for vehicular circulation and is necessary to achieve improved vehicle circulation within the development and on adjoining streets.

(d)        The Commission shall require the provision of adequate accessory off-street parking spaces and loading berths necessary to prevent the creation of traffic congestion caused by the curb parking of vehicles generated by any use permitted on the zoning lot, and shall determine the required number of parking spaces and loading berths in accordance with the purposes established in this Resolution with respect to other major traffic-generating facilities.

The Commission may prescribe appropriate conditions and safeguards to minimize adverse effects on the character of the surrounding area, and may require where the development or enlargement includes an active railroad or transit use, that the structural design of such development or enlargement make due allowance for changes within the layout of tracks or other structures within such railroad or transit air space or railroad or transit right-of-way or yard which may be deemed necessary in connection with future development or improvement of the transportation system.

Prior to granting a special permit, the Commission shall request the Metropolitan Transportation Authority and the Departments of Transportation of the State of New York and the City of New York to indicate within 30 days whether said agencies have any plan to use that portion of the railroad or transit air space or railroad or transit right-of-way or yard where the railroad or transit use has been permanently discontinued or terminated.

74-682 Developments Over Streets

In R9 or R10 Districts when the air space above a street or portion thereof is closed, demapped and conveyed by the City to the owner of an adjoining zoning lot owned by a non-profit institution pursuant to State-enabling legislation enacted in 1971, the City Planning Commission may, by special permit, allow in such demapped air space, the development or enlargement of buildings which are an expansion of an existing hospital, college, university or functionally-related facility. In connection therewith, the Commission may also permit modification of off-street loading and bulk regulations, except floor area ratio regulations, under the applicable district regulation, provided that the requirements set forth in the 1973 Agreement among the City of New York, the Society of the New York Hospital, and the New York Society for the Relief of the Ruptured and Crippled, maintaining the Hospital for Special Surgery and the Rockefeller University are met; and that such demapped air space shall be considered as part of the adjoining zoning lot, except that any building located in demapped air space shall utilize only unused floor area from the portion of the adjoining zoning lot not within the demapped air space.

In order to grant such special permit, the Commission shall find:

(a)        for development or enlargements in such demapped air space and for modification of bulk regulations, that the location and distribution of new bulk shall result in a good site plan in relation to the existing buildings on-site and in the area; and

(b)        for modification of off-street loading requirements, when such non-profit institution includes more than one building on two or more zoning lots, the Commission may determine the required number of loading berths as if such non-profit institution were located on a single zoning lot, and may permit such loading berths to be located anywhere within such institution without regard for zoning lot lines, provided that such loading berths shall be:

(1)        adequate to serve the requirements of the institution;

(2)        accessible to all the uses in such institution without the need to cross any street at grade; and

(3)        located so as not to adversely affect the movement of pedestrians or vehicles on the streets within or surrounding such institution.

The curb level of a zoning lot of which the demapped air space is a part shall not be affected by the closing and demapping of air space above such street. However, the Commission may establish an appropriate level or levels instead of curb level as the reference plane for the applicable regulations relating to open space, yards, level of yards, equivalent rear yards, rear yard setback, minimum distance between buildings, and the front height and setback.

The Commission may impose additional conditions and safeguards, consistent with the requirements set forth in the 1973 Agreement, to improve the quality of the development and minimize adverse effects on the character of the surrounding area.

Related Code Sections


Section 3201 Encroachments Into the Public Right-Of-Way, General
The provisions of this chapter shall govern the encroachment of structures into the public right-of-way ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3201 General
Section 3201 Encroachments Into the Public Right-Of-Way, General
The provisions of this chapter shall govern the encroachment of structures into the public right-of-way ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3201 General
1205.2.5 Interior Environment, Openings on Yards or Courts
Exterior glazed openings shall open directly onto a public street, space, alley, park, highway, or right of way; or upon a yard, court, plaza ...
NYC Building Code 2008 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.5 Openings on Yards or Courts
1205.2.5 Interior Environment, Openings on Yards or Courts
Exterior glazed openings shall open directly onto a public street, space, alley, park, highway, or right-of-way; or upon a yard, court, plaza ...
NYC Building Code 2014 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.5 Openings on Yards or Courts
3202.2.3.2 Encroachments Into the Public Right-Of-Way, Awnings Over Windows or Doors
Awnings over windows or doors may project beyond the street line not more than 5 feet (1524 mm), provided that no part of the awning is less than 8 ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.3 Awnings > 3202.2.3.2 Awnings Over Windows or Doors
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE