1615.2.3 Deterministic Maximum Considered Earthquake Ground Motion
Go To Full Code Chapter
The deterministic maximum considered earthquake ground motion response spectrum shall be calculated as 150 percent of the median spectral response accelerations, SaM, at all periods resulting from a characteristic earthquake on any known active fault within the region.