• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5605.4.1 Determination of Net Explosive Weight for Operating Buildings

Fire Code 2018 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings
JUMP TO FULL CODE CHAPTER
In addition to the requirements of Section 5601.8 to determine the net explosive weight for materials stored or used in operating buildings, quantities of explosive materials stored in magazines located at distances less than intraline distances from the operating building shall be added to the contents of the operating building to determine the net explosive weight for the operating building.

5605.4.1.1 Indoor Magazines

The storage of explosive materials located in indoor magazines in operating buildings shall be limited to a net explosive weight not to exceed 50 pounds (23 kg).

5605.4.1.2 Outdoor Magazines With a Net Explosive Weight Less Than 50 Pounds

The storage of explosive materials in outdoor magazines located at less than intraline distances from operating buildings shall be limited to a net explosive weight not to exceed 50 pounds (23 kg).

5605.4.1.3 Outdoor Magazines With a Net Explosive Weight Greater Than 50 Pounds

The storage of explosive materials in outdoor magazines in quantities exceeding 50 pounds (23 kg) net explosive weight shall be limited to storage in outdoor magazines located not less than intraline distances from the operating building in accordance with Section 5604.5.2.

5605.4.1.4 Net Explosive Weight of Materials Stored in Combination Indoor and Outdoor Magazines

The aggregate quantity of explosive materials stored in any combination of indoor magazines or outdoor magazines located at less than the intraline distances from an operating building shall not exceed 50 pounds (23 kg).

Related Code Sections


5605.4.1 Explosives and Fireworks, Determination of Net Explosive Weight for Operating Buildings
In addition to the requirements of Section 5601.8 to determine the net explosive weight for materials stored or used in operating buildings ...
Fire Code 2021 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings
5605.4.1 Explosives and Fireworks, Determination of Net Explosive Weight for Operating Buildings
In addition to the requirements of Section 5601.8 to determine the net explosive weight for materials stored or used in operating buildings ...
Fire Code 2018 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings
5605.4.1.3 Explosives and Fireworks, Outdoor Magazines With a Net Explosive Weight Greater Than 50 Pounds
The storage of explosive materials in outdoor magazines in quantities exceeding 50 pounds (23 kg) net explosive weight shall be limited to storage ...
Fire Code 2018 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings > 5605.4.1.3 Outdoor Magazines With a Net Explosive Weight Greater Than 50 Pounds
5605.4.1.4 Explosives and Fireworks, Net Explosive Weight of Materials Stored in Combination Indoor and Outdoor Magazines
distances from an operating building shall not exceed 50 pounds (23 kg) ...
Fire Code 2021 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings > 5605.4.1.4 Net Explosive Weight of Materials Stored in Combination Indoor and Outdoor Magazines
5605.4.1.4 Explosives and Fireworks, Net Explosive Weight of Materials Stored in Combination Indoor and Outdoor Magazines
distances from an operating building shall not exceed 50 pounds (23 kg) ...
Fire Code 2018 of Colorado > 56 Explosives and Fireworks > 5605 Manufacture, Assembly and Testing of Explosives, Explosive Materials and Fireworks > 5605.4 Separation of Manufacturing Operating Buildings From Inhabited Buildings, Public Traffic Routes and Magazines > 5605.4.1 Determination of Net Explosive Weight for Operating Buildings > 5605.4.1.4 Net Explosive Weight of Materials Stored in Combination Indoor and Outdoor Magazines
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING