406.12 Detectable Warnings at Raised Marked Crossings
JUMP TO FULL CODE CHAPTER
Marked crossings that are raised to the same level as the adjoining sidewalk shall be preceded by a detectable warning 24 inches (610 mm) in depth complying with Section 705. The detectable warning shall extend the full width of the marked crossing.
Related Code Sections
406.12 Accessible Routes, Detectable Warnings at Raised Marked Crossings
Marked crossings that are raised to the same level as the adjoining sidewalk shall be preceded by a detectable warning 24 inches (610 mm) in depth ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 406 Curb Ramps > 406.12 Detectable Warnings at Raised Marked Crossings
1109.10 Of the 2012 IBC With Minnesota Amendments, Detectable Warnings
have a detectable warning . Exception: Detectable warnings are not required at bus stops ...
Minnesota Accessibility Code 2015 > 11 Of the 2012 IBC With Minnesota Amendments > 1109 Other Features and Facilities > 1109.10 Detectable Warnings
805.10 Special Rooms and Spaces, Track Crossings
Where a circulation path crosses tracks, it shall comply with Section 402 and shall have a detectable warning 24 inches (610 mm) in depth complying ...
Minnesota Accessibility Code 2015 > 8 Special Rooms and Spaces > 805 Transportation Facilities > 805.10 Track Crossings
5003.8.7.2 Hazardous Materials—General Provisions, Warning Markings
Cabinets shall be clearly identified in an approved manner with red letters on a contrasting background to read: HAZARDOUS—KEEP FIRE AWAY ...
2020 Minnesota State Fire Code > 50 Hazardous Materials—General Provisions > 5003 General Requirements > 5003.8 Construction Requirements > 5003.8.7 Hazardous Materials Storage Cabinets > 5003.8.7.2 Warning Markings
5003.8.7.2 Hazardous Materials—General Provisions, Warning Markings
Cabinets shall be clearly identified in an approved manner with red letters on a contrasting background to read: HAZARDOUS—KEEP FIRE AWAY ...
Minnesota Fire Code 2015 > 50 Hazardous Materials—General Provisions > 5003 General Requirements > 5003.8 Construction Requirements > 5003.8.7 Hazardous Materials Storage Cabinets > 5003.8.7.2 Warning Markings