// CODE SNIPPET

Section 3204 Designation of High-Piled Storage Areas

California Fire Code 2016 > 32 High-Piled Combustible Storage > 3204 Designation of High-Piled Storage Areas
JUMP TO FULL CODE CHAPTER

3204.1 General

High-piled storage areas, and portions of high-piled storage areas intended for storage of a different commodity class than adjacent areas, shall be designed and specifically designated to contain Class I, Class II, Class III, Class IV or high-hazard commodities. The designation of a high-piled combustible storage area, or portion thereof intended for storage of a different commodity class, shall be based on the highest hazard commodity class stored except as provided in Section 3204.2.

3204.2 Designation based on engineering analysis

The designation of a high-piled combustible storage area, or portion thereof, is allowed to be based on a lower hazard class than that of the highest class of commodity stored when a limited quantity of the higher hazard commodity has been demonstrated by engineering analysis to be adequately protected by the automatic sprinkler system provided. The engineering analysis shall consider the ability of the sprinkler system to deliver the higher density required by the higher hazard commodity. The higher density shall be based on the actual storage height of the pile or rack and the minimum allowable design area for sprinkler operation as set forth in the density/area figures provided in NFPA 13. The contiguous area occupied by the higher hazard commodity shall not exceed 120 square feet (11 m2) and additional areas of higher hazard commodity shall be separated from other such areas by 25 feet (7620 mm) or more. The sprinkler system shall be capable of delivering the higher density over a minimum area of 900 square feet (84 m2) for wet pipe systems and 1,200 square feet (111 m2) for dry pipe systems. The shape of the design area shall be in accordance with Section 903.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


Section 3204 High-Piled Combustible Storage, Designation of High-Piled Storage Areas
designation of a high-piled combustible storage area, or portion thereof, is allowed to be based on a lower hazard class than that of the highest class ...
California Fire Code 2016 > 32 High-Piled Combustible Storage > 3204 Designation of High-Piled Storage Areas
3206.9.1.1 High-Piled Combustible Storage, Sprinklered buildings
Exception: Aisles in high-piled storage areas exceeding 2,500 square feet (232 m 2 ) in area, that are accessible to the public and designated ...
California Fire Code 2016 > 32 High-Piled Combustible Storage > 3206 General Fire Protection and Life Safety Features > 3206.9 Aisles > 3206.9.1 Width > 3206.9.1.1 Sprinklered buildings
3201.3 High-Piled Combustible Storage, Construction documents
design features, commodities, storage arrangement and fire protection features within the high-piled storage area shall be provided at the time ...
California Fire Code 2016 > 32 High-Piled Combustible Storage > 3201 General > 3201.3 Construction documents
3206.9 High-Piled Combustible Storage, Aisles
, that are accessible to the public and designated to contain high-hazard commodities. Exception: Aisles in high-piled storage areas exceeding 2,500 ...
California Fire Code 2016 > 32 High-Piled Combustible Storage > 3206 General Fire Protection and Life Safety Features > 3206.9 Aisles
Section 3201 High-Piled Combustible Storage, General
for new structures designed to accommodate high-piled storage or for requesting a change of occupancy/use, and at the time of application for a storage ...
California Fire Code 2016 > 32 High-Piled Combustible Storage > 3201 General
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US