1609.6.3.2 Design Wind Load Cases
JUMP TO FULL CODE CHAPTER
The main wind-force-resisting system of buildings, whose wind loads have been determined pursuant to Section 1609.6.3, shall be designed for wind load cases as defined below:
Case 1.
Full design wind pressure acting on the projected area perpendicular to each principal axis of the structure, considered separately along each principal axis.
Case 2.
Seventy-five percent of the design wind pressure acting on the projected area perpendicular to each principal axis of the structure to be applied eccentric to the center of the exposure with eccentricity equal to 15 percent of the exposure width, considered separately for each principal direction.
Case 3.
Wind loading as defined in Case 1 for each orthogonal direction, but considered to act simultaneously at 75 percent of the specified value.
Case 1.
Full design wind pressure acting on the projected area perpendicular to each principal axis of the structure, considered separately along each principal axis.
Case 2.
Seventy-five percent of the design wind pressure acting on the projected area perpendicular to each principal axis of the structure to be applied eccentric to the center of the exposure with eccentricity equal to 15 percent of the exposure width, considered separately for each principal direction.
Case 3.
Wind loading as defined in Case 1 for each orthogonal direction, but considered to act simultaneously at 75 percent of the specified value.
Related Code Sections
1609.6.3.2 Structural Design, Design Wind Load Cases
load cases as defined below: Case-1. Full design wind pressure acting on the projected area perpendicular to each principal axis ...
NYC Building Code 2008 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.3 Simplified Design Procedure-II > 1609.6.3.2 Design Wind Load Cases
1609.6.3.2 Structural Design, Design Wind Load Cases
load cases as defined below: Case 1. Full design wind pressure acting on the projected area perpendicular to each principal axis of the structure ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.3 Simplified Design Procedure II > 1609.6.3.2 Design Wind Load Cases
1609.6 Structural Design, Simplified Wind Load Methods
of buildings, whose wind loads have been determined pursuant to Section 1609.6.3, shall be designed for wind load cases as defined below: Case 1. Full ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods
Section 1609 Structural Design, Wind Loads
be designed for wind load cases as defined below: Case-1. Full design wind pressure acting on the projected area perpendicular to each ...
Section 1609 Structural Design, Wind Loads
loads have been determined pursuant to Section 1609.6.3, shall be designed for wind load cases as defined below: Case 1. Full design wind ...