• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1808.2.23.2.1 Design Details for Piers, Piles and Grade Beams

2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.23 Seismic Design of Piers or Piles > 1808.2.23.2 Seismic Design Category D, E or F > 1808.2.23.2.1 Design Details for Piers, Piles and Grade Beams
JUMP TO FULL CODE CHAPTER
Piers or piles shall be designed and constructed to withstand maximum imposed curvatures from earthquake ground motions and structure response. Curvatures shall include free-field soil strains modified for soil-pile-structure interaction coupled with pier or pile deformations induced by lateral pier or pile resistance to structure seismic forces. Concrete piers or piles on Site Class E or F sites, as determined in Section 1613.5.2, shall be designed and detailed in accordance with Sections 21.4.4.1, 21.4.4.2 and 21.4.4.3 of ACI 318 within seven pile diameters of the pile cap and the interfaces of soft to medium stiff clay or liquefiable strata. For precast prestressed concrete piles, detailing provisions as given in Sections 1809.2.3.2.1 and 1809.2.3.2.2 shall apply. Grade beams shall be designed as beams in accordance with ACI 318, Chapter 21. When grade beams have the capacity to resist the forces from the load combinations in Section 1605.4, they need not conform to ACI 318, Chapter 21.

Related Code Sections


1808.2.23.2.1 Soils and Foundations, Design Details for Piers, Piles and Grade Beams
Piers or piles shall be designed and constructed to withstand maximum imposed curvatures from earthquake ground motions and structure response ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.23 Seismic Design of Piers or Piles > 1808.2.23.2 Seismic Design Category D, E or F > 1808.2.23.2.1 Design Details for Piers, Piles and Grade Beams
1808.2.23.2.3 Soils and Foundations, Flexural Strength
strength. The connection between batter piles and grade beams or pile caps shall be designed to resist the nominal strength of the pile acting ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.23 Seismic Design of Piers or Piles > 1808.2.23.2 Seismic Design Category D, E or F > 1808.2.23.2.3 Flexural Strength
1808.2.4 Soils and Foundations, Pile Caps
Pile caps shall be of reinforced concrete, and shall include all elements to which piles are connected, including grade beams and mats. The soil ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.4 Pile Caps
1808.2.23.1.2 Soils and Foundations, Design Details
Pier or pile moments, shears and lateral deflections used for design shall be established considering the nonlinear interaction of the shaft and soil ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.23 Seismic Design of Piers or Piles > 1808.2.23.1 Seismic Design Category C > 1808.2.23.1.2 Design Details
1810.3.12 Soils and Foundations, Grade Beams
For structures assigned to Seismic Design Category D, E or F, grade beams shall comply with the provisions in Section 18.13.3 of ACI 318 for grade ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.3 Design and Detailing > 1810.3.12 Grade Beams
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE