1808.9.2.2 Design Details
JUMP TO FULL CODE CHAPTER
Pile moments, shears and lateral deflections used for design shall be established considering the nonlinear interaction of the shaft and soil, as recommended by the engineer. Where the ratio of the depth of embedment of the pile-to-pile diameter or width is less than or equal to six, the pile may be assumed to be rigid. Pile group effects from soil on lateral pile nominal strength shall be included where pile center-to-center spacing in the direction of lateral force is less than eight pile diameters. Pile group effects on vertical nominal strength shall be included where pile center-to-center spacing is less than three pile diameters. The pile uplift soil nominal strength shall be taken as the pile uplift strength as limited by the frictional force developed between the soil and the pile.
Where a minimum length for reinforcement or the extent of closely spaced confinement reinforcement is specified at the top of the pile, provisions shall be made so that those specified lengths or extents are maintained after pile cutoff.
Where a minimum length for reinforcement or the extent of closely spaced confinement reinforcement is specified at the top of the pile, provisions shall be made so that those specified lengths or extents are maintained after pile cutoff.
Related Code Sections
1808.2.23.1.2 Soils and Foundations, Design Details
Pier or pile moments, shears and lateral deflections used for design shall be established considering the nonlinear interaction of the shaft and soil ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.23 Seismic Design of Piers or Piles > 1808.2.23.1 Seismic Design Category C > 1808.2.23.1.2 Design Details
1808.9.2.2 Soils and Foundations, Design Details
Pile moments, shears and lateral deflections used for design shall be established considering the nonlinear interaction of the shaft and soil ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.9 Seismic Design Categories C & D > 1808.9.2 Seismic Design Category C > 1808.9.2.2 Design Details
1620.1 Structural Design, Structural Component Design and Detailing
The design and detailing of the components of the seismic-force-resisting system shall comply with the requirements of Section 9.5.2.6 ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.1 Structural Component Design and Detailing
1620.1.3 Structural Design, ASCE 7, Section 9.5.2.6.3
Modify ASCE 7, Section 9.5.2.6.3, to read as follows:
9.5.2.6.3 Seismic Design Category C. Structures assigned to Category C shall conform ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.1 Structural Component Design and Detailing > 1620.1.3 ASCE 7, Section 9.5.2.6.3
1620.3 Structural Design, Seismic Design Category C
Structures assigned to Seismic Design Category C (see Section 1616) shall conform to the requirements of Section 1620.2 for Seismic ...
NYC Building Code 2008 > 16 Structural Design > 1620 Earthquake Loads — Design, Detailing Requirements and Structural Component Load Effects > 1620.3 Seismic Design Category C