• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1230.1 Design Criteria for Required Spaces

Los Angeles Building Code > 12 Interior Environment > 1230 [BSCC] Minimum Standards for Juvenile Facilities > 1230.1 Design Criteria for Required Spaces
JUMP TO FULL CODE CHAPTER

1230.1.1 Reception/Intake Admission

In each juvenile hall, space used for the reception of minors pending admission to juvenile hall shall have the following space and equipment:

  1. Weapons lockers as specified in Section 1230.2.9;
  2. A secure room for the confinement of minors pending admission to juvenile hall as specified in Section 1230.1.2;

    In each juvenile hall, camp and ranch, space used for the reception of minors pending admission to these facilities shall have the following space and equipment:

  3. Access to a shower;
  4. A secure vault or storage space for minors, valuables;
  5. Telephones accessible to minors; and
  6. Access to hot and cold running water for staff use.

1230.1.2 Locked Holding Room

A locked holding room shall:

  1. Contain a minimum of 15 square feet (1.4 m2) of floor area per youth;
  2. Provide no less than 45 square feet (4.2 m2) of floor space and have a clear ceiling height of 8 feet (2438 mm) or more;
  3. Contain seating to accommodate all youth as specified in Section 1230.2.8;
  4. Be equipped with a toilet, wash basin and drinking fountain as specified in Section 1230.2, unless a procedure is in effect to give the youth access to a toilet, wash basin and drinking fountain;
  5. Maximize visual supervision of youth by staff; and
  6. Have an outward swinging or lateral sliding door.

1230.1.3 Natural Light

Visual access to natural light shall be provided in locked sleeping rooms, single occupancy sleeping rooms, double occupancy sleeping rooms, dormitories and day rooms. Natural light may be provided by, but is not limited to, skylights or windows in dayrooms, windows in adjacent exterior exercise areas, and in sleeping rooms and/or dormitories.

1230.1.4 Corridors

Corridors in living units shall be at least 8 feet (2438 mm) wide.

Exception: Where room doors are staggered, or if rooms are located on only one side, corridors shall be at least 6 feet (1829 mm) wide.

1230.1.5 Living Unit

A living unit shall be a self-contained unit containing locked sleeping rooms, single and double occupancy sleeping rooms, or dormitories, day-room space, toilet, wash basins, drinking fountains and showers commensurate to the number of youth housed. A living unit shall not be divided in a way that hinders direct access, supervision, immediate intervention or other action if needed. In juvenile halls, the number of youth housed in a living unit shall not exceed 30.

1230.1.6 Locked Sleeping Rooms

Locked sleeping rooms shall be equipped with an individual or combination toilet, wash basin and drinking fountain. Doors to locked sleeping rooms shall swing outward or slide laterally.

1230.1.7 Single Occupancy Sleeping Rooms

Single occupancy sleeping rooms shall provide the following:

  1. A minimum of 70 square feet (1.78 m2) of floor area;
  2. A minimum clear ceiling height of 8 feet (2438 mm); and,
  3. The door into this room shall swing outward or slide laterally and be provided with a view panel, a minimum of 144 square inches (92,903 mm2), constructed of security glazing.

1230.1.8 Double Occupancy Sleeping Rooms

Double occupancy sleeping rooms shall provide the following:

  1. A minimum of 100 square feet (9.3 m2) of floor area;
  2. A minimum clear ceiling height of 8 feet (2438 mm) and a minimum width of 7 feet (2134 mm); and,
  3. The door into this room shall swing outward or slide laterally and be provided with a view panel, a minimum of 144 square inches (92,903 mm2), constructed of security glazing.

1230.1.9 Dormitories

Dormitories shall provide the following:

  1. A minimum of 50 square feet (4.6 m2) of floor area per minor with the minimum size of a dormitory being 200 square feet (18.6 m2) of floor area and a minimum 8-foot (2438 mm) clear ceiling height;
  2. Designed for no fewer than four minors;
  3. Dormitories in juvenile halls shall be designed for no more than 30 minors;
  4. Camps shall conform to Items 1 and 2.

1230.1.10 Dayrooms

Dayrooms shall contain 35 square feet (3.3 m2) of floor area per minor. Access must be provided to toilets, wash basins, drinking fountains and showers as specified in Section 1230.2.

1230.1.11 Physical Activity and Recreation Areas

Indoor / outdoor physical activity and recreation areas shall be designed as follows:

  1. 1.Facility capacityMinimum indoor outdoor recreation space
    40 or less9,000 square feet (836 m2)
    41 to 274225 square feet (21 m2) perminor up to 61,650 square feet (5727 m2)
    275 or more61,650 square feet (5727 m2), plus 145 square feet (13.47 m2) for each minor beyond 274 [up to a maximum of 87,120 square feet (8093 m2)]
    1. 1.1. At least one quarter of the dedicated indoor/outdoor space shall be a paved or like surface.
    2. 1.2. The required recreation area shall contain no single dimension less than 40 feet (12.2 m).
  2. A portion of the dedicated space for physical activity and recreation shall be out-of-doors and be of sufficient size and equipped in such a manner to allow compliance with Title 15, Section 1371, which requires at least one hour per day of outdoor activity for each detained minor.
  3. Lighting of outdoor recreation areas shall be provided to allow for evening activities and to provide security.
  4. Access must be provided to a toilet, wash basin and drinking fountain as specified in Section 1230.2.

1230.1.12 Academic Classrooms

There shall be dedicated classroom space for every juvenile in every facility. The primary purpose for the academic classroom shall be for education. Each academic classroom shall contain a minimum of 160 square feet (14.9 m2) of floor space for the teachers' desk and work area and a minimum of 28 square feet (2.6 m2) of floor space per minor. A communication system shall be provided in each classroom to allow for immediate response to emergencies. The classroom shall be designed for a maximum of 20 minors.

1230.1.13 Safety Room

A safety room shall:

  1. Contain a minimum of 63 square feet (5.9 m2) of floor area and a minimum clear ceiling height of 8 feet (2438 mm);
  2. Be limited to one minor;
  3. Be padded as specified in Section 1230.2.7;
  4. Provide one or more vertical view panels constructed of security glazing. These view panels shall be no more than 4 inches (102 mm) wide nor less than 24 inches (610 mm) long, which shall provide a view of the entire room;
  5. Provide an audio monitoring system as specified in Section 1230.1.22;
  6. Provide access to a toilet, wash basin and drinking fountain outside the room as specified in Section 1230.2; and
  7. Be equipped with a variable intensity, security-type lighting fixture with controls located outside the room.
  8. Any wall or ceiling-mounted devices must be designed to prohibit access to the minor occupant.

1230.1.14 Medical Examination Room

There must be a minimum of one suitably equipped medical examination room in every juvenile facility. Medical examination rooms shall provide the following:

  1. Space for carrying out routine medical examinations and emergency care and used for no other purpose;
  2. Privacy for minors;
  3. Lockable storage space for medical supplies;
  4. Not less than 144 square feet (13.4m2) of floor space with no single dimension less than 7 feet (2134 mm);
  5. Hot and cold running water; and
  6. Smooth, nonporous, washable surfaces.

1230.1.15 Pharmaceutical Storage

Provide lockable storage space for medical supplies and pharmaceutical preparations as specified by Title 15, Section 1438.

1230.1.16 Dining Areas

Dining areas in juvenile facilities shall contain a minimum of 15 square feet (1.4 m2) of floor space and sufficient tables and seating for each person being fed. Persons being fed include minors, staff and visitors. Dining areas shall not contain toilets or showers in the same room without appropriate visual barrier.

1230.1.17 Visiting Space

Space shall be provided in all juvenile facilities for visiting.

1230.1.18 Institutional Storage

One or more storage rooms shall be provided to accommodate a minimum of 80 cubic feet (2.3 m3) of storage space per minor. Items to be stored shall be institutional clothing, bedding, supplies and activity equipment.

1230.1.19 Personal Storage

Each minor in a juvenile facility shall be provided with a minimum of 9 cubic feet (0.25 m3) of secure storage space for personal clothing and belongings.

1230.1.20 Safety Equipment Storage

In all juvenile facilities, a secure area shall be provided for the storage of safety equipment, such as fire extinguishers, self-contained breathing apparatus, wire and bar cutters, emergency lights, etc.

1230.1.21 Janitorial Closet

In all juvenile facilities, at least one securely lockable janitorial closet, containing a mop sink and sufficient area for the storage of cleaning implements, must be provided within the security area of the facility.

1230.1.22 Audio Monitoring System

In safety rooms, locked holding rooms, locked sleeping rooms, single and double occupancy rooms and dormitories, there must be an audio monitoring system capable of actuation by the minor that alerts personnel.

1230.1.23 Emergency Power

There shall be a source of emergency power in all juvenile facilities capable of providing minimal lighting in all living units, activities areas, corridors, stairs and central control points, and to maintain fire and life safety, security, communications and alarm systems (Title 24, Part 2, Chapter 27). Such an emergency power source shall conform to the requirements specified in Title, 24, Part 3, Article 700, California Electrical Code, California Code of Regulations.

1230.1.24 Confidential Interview Room

Confidential interview rooms shall contain a minimum of 60 square feet (5.6 m2) of floor area. In juvenile halls there shall be a minimum of one suitably furnished interview room for each 30 minors. In camps there shall be a minimum of one suitably furnished interview room for each facility. This interview room shall provide for confidential consultations with minors.

1230.1.25 Special-Purpose Juvenile Halls

Special-purpose juvenile halls shall conform to all minimum standards for juvenile facilities contained in this section with the following exceptions:

  1. Physical activity and recreation areas as specified in Section 1230.1.11;
  2. Academic classrooms as specified in Section 1230.1.12;
  3. Medical examination room as specified in Section 1230.1.14; and,
  4. Dining areas as specified in Section 1230.1.16.

1230.1.26 Court Holding Room for Minors

A court holding room shall:

  1. Contain a minimum of 10 square feet (0.93 m2) of floor area per minor;
  2. Be limited to no more than 16 minors;
  3. Provide no less than 40 square feet (3.7 m2) of floor area and have clear ceiling height of 8 feet (2438 mm) or more;
  4. Contain seating to accommodate all minors as specified in Section 1230.2.8;
  5. Contain a toilet, wash basin and drinking fountain as specified in Section 1230.2; and,
  6. Maximize visual supervision of minors by staff.

1230.1.27 Program and Activity Areas

Camp and ranch facilities shall include adequate space for specific programs in addition to recreation and exercise areas.

Related Code Sections


1230.1 Interior Environment, Design Criteria for Required Spaces
(8093 m 2 )] 1.1. At least one quarter of the dedicated indoor/outdoor space shall be a paved or like surface. 1.2. The required recreation area ...
Los Angeles Building Code > 12 Interior Environment > 1230 [BSCC] Minimum Standards for Juvenile Facilities > 1230.1 Design Criteria for Required Spaces
1231.2 Interior Environment, Design Criteria for Required Spaces
with inmates. Exception: The design of court holding and temporary holding facilities shall include the following required spaces from Sections ...
Los Angeles Building Code > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.2 Design Criteria for Required Spaces
1231.2.1 Interior Environment, Reception and Booking
Facilities where booking and housing occur shall have the following space and equipment: Weapons locker as specified in Section 1231.3.12. A cell ...
Los Angeles Building Code > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.2 Design Criteria for Required Spaces > 1231.2.1 Reception and Booking
1231.2.9 Interior Environment, Dayrooms
Dayrooms or dayroom space shall: Contain 35 square feet (3.3 m 2 ) of floor area per inmate in width in front of cells/rooms; Contain tables ...
Los Angeles Building Code > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.2 Design Criteria for Required Spaces > 1231.2.9 Dayrooms
1231.2.10 Interior Environment, Exercise Area
design shall facilitate security and supervision appropriate to the level of custody. Type IV facilities shall have an outdoor recreation area ...
Los Angeles Building Code > 12 Interior Environment > 1231 [BSCC] Local Detention > 1231.2 Design Criteria for Required Spaces > 1231.2.10 Exercise Area
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE