Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2411.3.1 Design and Approval

2020 FBC - Building, 7th edition > 24 Glass and Glazing > 2411 High-Velocity Hurricane Zones—Windows, Doors, Glass and Glazing > 2411.3 Doors and Operative Windows in Exterior Walls > 2411.3.1 Design and Approval
JUMP TO FULL CODE CHAPTER

2411.3.1.1

The design and approval of sliding doors, swinging doors and operative windows in exterior walls, including the supporting members shall be based on the proposed use-height above grade in accordance with Chapter 16 (High-Velocity Hurricane Zones).

2411.3.1.2

Maximum glass sizes shall comply with ASTM E1300.

2411.3.1.3

Reserved.

2411.3.1.4

The architect or professional engineer of record shall be required to specify the design wind pressure, determined in accordance with Chapter 16 (High-Velocity Hurricane Zones), for all garage doors, skylights operative windows and fixed glazing. The design wind pressure for each component of the exterior building surface shall be incorporated into the building design drawing so as to allow the respective manufacturer to size the prefabricated assembly for the proper wind pressures.

2411.3.1.5

Exterior garage doors shall be designed and constructed to actively or passively lock in the closed position when subjected to a uniform lateral pressure in excess of 50 percent of the design wind pressure as prescribed in Chapter 16 (High-Velocity Hurricane Zones).

2411.3.1.6

The architect or professional engineer of record shall be required to detail on the drawings submitted for permit, rough opening dimensions, supporting framework, method of attachment and waterproofing procedures for all garage doors, passage doors, skylights, operative and inoperative windows in exterior walls. Said framework and method of attachment shall be designed and constructed so as to sufficiently resist the design wind pressures as outlined in Chapter 16 (High-Velocity Hurricane Zones).
Exception: When detailed engineered shop drawings, along with the notices of product approval, produced by the manufacturer's specialty engineer and approved by the architect or professional engineer of record, are admitted at the time of permit application, which completely identifies rough openings, supporting framework, method of attachment and waterproofing procedures are prepared and bear the signature and seal of a professional engineer.

Related Code Sections


2411.3.1 Glass and Glazing, Design and Approval
The design and approval of sliding doors, swinging doors and operative windows in exterior walls, including the supporting members shall be based ...
2017 FBC - Building, 6th edition > 24 Glass and Glazing > 2411 High-Velocity Hurricane Zones— Windows, Doors, Glass and Glazing > 2411.3 Doors and Operative Windows in Exterior Walls > 2411.3.1 Design and Approval
2411.3.1 Glass and Glazing, Design and Approval
The design and approval of sliding doors, swinging doors and operative windows in exterior walls, including the supporting members shall be based ...
2020 FBC - Building, 7th edition > 24 Glass and Glazing > 2411 High-Velocity Hurricane Zones—Windows, Doors, Glass and Glazing > 2411.3 Doors and Operative Windows in Exterior Walls > 2411.3.1 Design and Approval
2411.3.1 Glass and Glazing, Design and Approval
The design and approval of sliding doors, swinging doors and operative windows in exterior walls, including the supporting members, shall be based ...
2014 FBC - Building, 5th edition > 24 Glass and Glazing > 2411 High-Velocity Hurricane Zones— Windows, Doors, Glass and Glazing > 2411.3 Doors and Operative Windows in Exterior Walls > 2411.3.1 Design and Approval
42.10.3.1.1.6 Refueling, System Design and Approval
Work shall not be started on the construction or alteration of an airport fuel system until the design, plans, and specifications have been approved ...
NFPA 1 part of the 2020 FFPC, 7th edition > 42 Refueling > 42.10 Aircraft Fuel Servicing > 42.10.3 Aviation Fueling Facilities > 42.10.3.1 Design and Construction > 42.10.3.1.1 General Requirements > 42.10.3.1.1.6 System Design and Approval
453.27.2 Special Detailed Requirements Based on Use and Occupancy, Design, Plan Approval, Construction
registered design professionals and submitted to the authority having jurisdiction for review and approval for compliance with Florida laws, rules, building ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 453 State Requirements for Educational Facilities > 453.27 New Relocatable Buildings > 453.27.2 Design, Plan Approval, Construction
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.