• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BC] Section 103 Department of Buildings

NYC Building Code 2014 > 1 Administration > 103 Department of Buildings
JUMP TO FULL CODE CHAPTER

103.1 General

Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code.

Related Code Sections


Section 103 Administration, Department of Buildings
Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code ...
NYC Mechanical Code 2008 > 1 Administration > 103 Department of Buildings
Section 103 Administration, Department of Buildings
Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code ...
NYC Mechanical Code 2014 > 1 Administration > 103 Department of Buildings
Section 103 Administration, Department of Buildings
Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code ...
NYC Plumbing Code 2008 > 1 Administration > 103 Department of Buildings
Section 103 Administration, Department of Buildings
Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code ...
NYC Building Code 2008 > 1 Administration > 103 Department of Buildings
Section 103 Administration, Department of Buildings
Refer to the New York City Charter and Chapter 1 of Title 28 of the Administrative Code ...
NYC Building Code 2014 > 1 Administration > 103 Department of Buildings
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE