2703.11.3.1 Density
JUMP TO FULL CODE CHAPTER
Storage and display of solids shall not exceed 200 pounds per square foot (976 kg/m2) of floor area actually occupied by solid merchandise. Storage and display of liquids shall not exceed 20 gallons per square foot (0.50 L/m2) of floor area actually occupied by liquid merchandise.
Related Code Sections
1704.12.5 Structural Tests and Special Inspections, Density
The density of the sprayed fire-resistant material shall not be less than the density specified in the approved fire-resistance design. Density ...
2012 North Carolina Building Code > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.12 Sprayed Fire-Resistant Materials > 1704.12.5 Density
1705.14.5 Special Inspections and Tests, Density
The density of the sprayed fireresistant material shall not be less than the density specified in the approved fire-resistance design. Density ...
2018 North Carolina Building Code > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.14 Sprayed Fire-Resistant Materials > 1705.14.5 Density
2604.2.1 Plastic, Density
The minimum density of the interior trim shall be 20 pcf (320 kg/m 3 ) ...
2012 North Carolina Building Code > 26 Plastic > 2604 Interior Finish and Trim > 2604.2 Interior Trim > 2604.2.1 Density
2604.2.1 Plastic, Density
The minimum density of the interior trim shall be 20 pcf (320 kg/m 3 ) ...
2018 North Carolina Building Code > 26 Plastic > 2604 Interior Finish and Trim > 2604.2 Interior Trim > 2604.2.1 Density
2703.11.3.1 Hazardous Materials - General Provisions, Density
Storage and display of solids shall not exceed 200 pounds per square foot (976 kg/m 2 ) of floor area actually occupied by solid merchandise. Storage ...
2012 North Carolina Fire Code > 27 Hazardous Materials - General Provisions > 2703 General Requirements > 2703.11 Group M Storage and Display and Group S Storage > 2703.11.3 Storage and Display > 2703.11.3.1 Density