• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section A-303 Demolition and Relocation of Structures

Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures
JUMP TO FULL CODE CHAPTER

A-303.1 Service Connections

Before a structure is demolished or removed, the Demolition Contractor licensed pursuant to § 9-1008 of The Philadelphia Code responsible for the demolition shall notify all utilities having service connections within the structure such as water, electric, gas, sewer and other connections. Service connections and appurtenant equipment, such as meters and regulators shall be removed or sealed and plugged in a safe manner.

A-303.2 Posting and Notice

Upon submittal of an application for a permit for the demolition of a structure, the department shall provide a notice to the Demolition Contractor to be posted prior to the demolition of the structure. The Demolition Contractor shall post such notice on the structure to be demolished. Upon issuance of the building permit for the demolition, and in addition to the notification requirements for contractors established in this Section and the Building Code, the department is authorized to distribute an informational bulletin indicating that the City or owner intends to demolish said structure. The department shall distribute the informational bulletin to the properties located within a 100 foot radius of the subject property. The requirement to distribute an informational bulletin shall not create any actionable right for any resident or owner of the subject property or any neighboring property.

Exceptions:
  1. In the event of an emergency which requires immediate action to protect the health or safety of the public, which shall include any time the Department has served notice of a requirement to demolish an imminently dangerous structure under Section PM-110.2 of this Title and demolition is carried out within 10 days of service by the Department of the notice requiring demolition; provided that the Department distributes the informational bulletin to any property abutting the property on which a structure is to be demolished.
  2. When the structure has been posted as required by Section 14-303(13) of The Philadelphia Code.
  3. When the structure has been the subject of a variance granted by the Zoning Board of Adjustment.

UpCodes note: Section A-303.2 was amended by Bill No. 020411 (approved October 15, 2002), Bill No. 120774-A (approved January 14, 2013), Bill No. 130691-A (approved February 19, 2014), Bill No. 140856 (approved December 19, 2014), effective July 1, 2015, and Bill No. 180175 (approved June 6, 2018).

A-303.2.1 Location and Time

The notice shall be posted by the Demolition Contractor on each street frontage of the premises with which the notice is concerned. Posted notices shall remain until demolition of the structure, which shall not commence less than 21 days from the date of the initial posting of the notice.

UpCodes note: Section A-303.2.1 was amended by Bill No. 020411 (approved October 15, 2002), and Bill No. 180175 (approved June 6, 2018).

A-303.2.2 Content

Such posted notice shall be clearly visible to the public. All notices shall contain the date on which the permit application for demolition was submitted to the Department.

UpCodes note: Section A-303.2.2 was amended by Bill No. 020411. The bill was approved on October 15, 2002.

A-303.2.3 Removal

No person shall remove such notice prior to the approved date on which demolition is permitted to commence, unless the owner notifies the department that the structure will not be demolished and the permit has been revoked by the department upon such request, in which case, the Demolition Contractor shall remove the notice.

A-303.2.4 Penalties

Any Demolition Contractor who violates the provisions of this Section shall be subject to penalties as prescribed in Chapter 6.

A-303.2.5 Additional Posting and Notice

The Department shall include in any informational bulletin distributed pursuant to this Section all of the following: education material explaining the inherent safety risks of demolition; contractor obligations regarding party walls; information concerning shoring and bracing of walls; waterproofing and enclosure of breaches for interior walls that become exterior walls, and other required finishings.

UpCodes note: Section A-303.2.5 was amended by Bill No. 130691-A (approved February 19, 2014), and Bill No. 180175 (approved June 6, 2018).

A-303.3 Permits

A demolition permit shall be valid only in connection with work performed by the licensed Demolition Contractor identified on the permit. A Demolition Contractor that seeks to perform demolition work under a permit identifying another contractor must obtain an amendment of such permit that authorizes work by the new Demolition Contractor.

UpCodes note: Section A-303.3 was amended by Bill No. 180175. The bill was approved on June 6, 2018.

A-303.4 Moved Structures

Before any structure which has been moved is occupied, the structure and mechanical equipment shall be inspected for safe use and operation and for compliance with applicable provisions of this code and the technical codes.

Related Code Sections


Section A-303 Permits, Demolition and Relocation of Structures
Before a structure is demolished or removed, the Demolition Contractor licensed pursuant to § 9-1008 of The Philadelphia Code responsible ...
Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures
A-303.2.1 Permits, Location and Time
shall remain until demolition of the structure, which shall not commence less than 21 days from the date of the initial posting of the notice ...
Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures > A-303.2 Posting and Notice > A-303.2.1 Location and Time
A-303.2.2 Permits, Content
Such posted notice shall be clearly visible to the public. All notices shall contain the date on which the permit application for demolition ...
Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures > A-303.2 Posting and Notice > A-303.2.2 Content
A-303.2.4 Permits, Penalties
Any Demolition Contractor who violates the provisions of this Section shall be subject to penalties as prescribed in Chapter 6 ...
Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures > A-303.2 Posting and Notice > A-303.2.4 Penalties
A-303.2.5 Permits, Additional Posting and Notice
the inherent safety risks of demolition; contractor obligations regarding party walls; information concerning shoring and bracing of walls ...
Philadelphia Administrative Code > 3 Permits > A-303 Demolition and Relocation of Structures > A-303.2 Posting and Notice > A-303.2.5 Additional Posting and Notice
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE