• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2.4.6 Demand on Parts and Portions of the Building

California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.4 Analysis of the Building > 2.4.6 Demand on Parts and Portions of the Building
JUMP TO FULL CODE CHAPTER

Parts and portions of structures and permanent nonstructural components and equipment supported by a structure and their attachments, as identified in the building evaluation procedures, shall be evaluated to verify that they are capable of resisting the seismic forces specified below. All attachments or appendages, including anchorages and required bracing, shall be evaluated for seismic forces. Nonrigid equipment, the structural failure of which would cause a life-safety hazard, also shall be evaluated.

Each element or component evaluated shall be capable of resisting a total lateral seismic force, Fp, where:

(2-10)

where:

Av = the velocity-related acceleration coefficient given in Figures 2.1 and 2.1a.

Cc = a coefficient given in Table 2.4.6.

Wc = the weight of the element or component.

The NPC of the building shall be determined using the procedures in Article 11.

TABLE 2.4.6—

SEISMIC COEFFICIENT, Cc

Cc
Parts of structure Walls:
Unbraced (cantilevered parapets and walls) 2.4
Other exterior walls at and above the ground floor 0.9
All interior bearing and nonbearing walls and partitions 0.9
Masonry or concrete fences over 6 feet high 0.9
Penthouse (except where framed by an extension of the building frame) 0.9
Connections for prefabricated structural elements other than walls with force applied at the center of gravity 0.9
Nonstructural components Exterior and interior ornamentations and appendages 2.4
Chimneys, stacks, trussed towers and tanks:
Supported on or projecting as an unbraced cantilever above the roof more than one-half its total height 2.4
All others including those supported below the roof with unbraced projection above the roof less than one-half its height or braced or guyed to the structural frame at or above its center of mass 0.9
Mechanical, plumbing and electrical equipment 0.9
Anchorage for suspended ceilings and light fixtures 0.9

Related Code Sections


2.4.6 Seismic Evaluation Procedures for Hospital Buildings, Demand on Parts and Portions of the Building
Parts and portions of structures and permanent nonstructural components and equipment supported by a structure and their attachments, as identified ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.4 Analysis of the Building > 2.4.6 Demand on Parts and Portions of the Building
2.4.6 Seismic Evaluation Procedures for Hospital Buildings, Demand on Parts and Portions of the Building
Parts and portions of structures and permanent nonstructural components and equipment supported by a structure and their attachments, as identified ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 2 Procedures for Structural Evaluation of Buildings > 2.4 Analysis of the Building > 2.4.6 Demand on Parts and Portions of the Building
5.4.3 Seismic Evaluation Procedures for Hospital Buildings, Proportions
for parts and portions of a building given in Section 2.4.6 ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 5 Procedures for Shear Walls > 5.4 Unreinforced Masonry Shear Walls > 5.4.3 Proportions
5.4.3 Seismic Evaluation Procedures for Hospital Buildings, Proportions
the procedure for parts and portions of a building given in Section 2.4.6 ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 5 Procedures for Shear Walls > 5.4 Unreinforced Masonry Shear Walls > 5.4.3 Proportions
5.4 Seismic Evaluation Procedures for Hospital Buildings, Unreinforced Masonry Shear Walls
the out-of-plane demand using the procedure for parts and portions of a building given in Section 2.4.6 ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 5 Procedures for Shear Walls > 5.4 Unreinforced Masonry Shear Walls
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE