• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1008.1.9.7.1 Delayed Egress Locks in I-2 Occupancies

Ohio Building Code 2011 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.7 Delayed Egress Locks > 1008.1.9.7.1 Delayed Egress Locks in I-2 Occupancies
JUMP TO FULL CODE CHAPTER

Delayed egress locks shall be permitted in I-2 occupancies where the clinical needs of persons receiving care require such locking and where the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or an approved automatic smoke or heat detection system installed in accordance with Section 907, provided that the doors unlock in accordance with Items 1 through 6 below. A building occupant shall not be required to pass through more than one door equipped with a special egress lock before entering an exit.

  1. The doors unlock upon actuation of the automatic sprinkler system or automatic fire detection system.
  2. The doors unlock upon loss of power controlling the lock or lock mechanism.
  3. The door locks shall have the capability of being unlocked by a signal from the fire command center, a nursing station or other approved location.
  4. The procedures for the operation(s) of the unlocking system shall be described and approved as part of the emergency planning and preparedness required by Chapter 4 of the fire code.
  5. All clinical staff shall have the keys, codes or other means necessary to operate the locking devices.
  6. Emergency lighting shall be provided at the door.

Exception: Items 1 through 3 shall not apply to doors to areas where persons, because of clinical needs, require restraint or containment as part of the function of a mental hospital.

Related Code Sections


1008.1.9.7.1 Means of Egress, Delayed Egress Locks in I-2 Occupancies
Delayed egress locks shall be permitted in I-2 occupancies where the clinical needs of persons receiving care require such locking and where ...
Ohio Building Code 2011 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.7 Delayed Egress Locks > 1008.1.9.7.1 Delayed Egress Locks in I-2 Occupancies
1008.1.9.6 Ohio Administrative Code 1301:7-7-10 Means of Egress, Special Egress Locks for Group I-2
Approved delayed egress locks shall be permitted in I-2 occupancies where the clinical needs of persons ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.6 Special Egress Locks for Group I-2
1010.1.9 Means of Egress, Door Operations
one delayed egress locking system. Exception: In Group I-2 or I-3 occupancies, the egress path from any point in the building shall pass through ...
Ohio Building Code 2017 > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.9 Door Operations
907.4.2 Ohio Administrative Code 1301:7-7-09 Fire Protection Systems, Delayed Egress Locks
Where delayed egress locks are installed on means of egress doors in accordance with paragraph (H)(1)(i)(vi)(1008.1.9.6) of rule 1301:7-7-10 ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-09 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.4 Fire Safety Functions > 907.4.2 Delayed Egress Locks
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE