Section 1602 Definitions and Notations

Building Code 2015 of Utah > 16 Structural Design > 1602 Definitions and Notations
JUMP TO FULL CODE CHAPTER

1602.1 Definitions

The following terms are defined in Chapter 2:

ALLOWABLE STRESS DESIGN.

DEAD LOADS.

DESIGN STRENGTH.

DIAPHRAGM.

Diaphragm, blocked.

Diaphragm boundary.

Diaphragm chord.

ESSENTIAL FACILITIES.

FABRIC PARTITION.

FACTORED LOAD.

HELIPAD.

ICE-SENSITIVE STRUCTURE.

IMPACT LOAD.

LIMIT STATE.

LIVE LOAD.

LIVE LOAD (ROOF).

LOAD AND RESISTANCE FACTOR DESIGN (LRFD).

LOAD EFFECTS.

LOAD FACTOR.

LOADS.

NOMINAL LOADS.

OTHER STRUCTURES.

PANEL (PART OF A STRUCTURE).

RESISTANCE FACTOR.

RISK CATEGORY.

STRENGTH, NOMINAL.

STRENGTH, REQUIRED.

STRENGTH DESIGN.

SUSCEPTIBLE BAY.

VEHICLE BARRIER.

NOTATIONS.

D = Dead load.
Di = Weight of ice in accordance with Chapter 10 of ASCE 7.
E = Combined effect of horizontal and vertical earthquake induced forces as defined in Section 12.4.2 of ASCE 7.
F = Load due to fluids with well-defined pressures and maximum heights.
Fa = Flood load in accordance with Chapter 5 of ASCE 7.
H = Load due to lateral earth pressures, ground water pressure or pressure of bulk materials.
L = Roof live load greater than 20 psf (0.96 kN/m2) and floor live load.
Lr = Roof live load of 20 psf (0.96 kN/m2) or less.
R = Rain load.
S = Snow load.
T = Self-straining load.
Vasd = Nominal design wind speed (3-second gust), miles per hour (mph) (km/hr) where applicable.
Vult = Ultimate design wind speeds (3-second gust), miles per hour (mph) (km/hr) determined from Figure 1609.3(1), 1609.3(2), 1609.3(3) or ASCE 7.
W = Load due to wind pressure.
Wi = Wind-on-ice in accordance with Chapter 10 of ASCE 7.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


Section 1602 Structural Design, Definitions and Notations
BARRIER. NOTATIONS. D = Dead load. D i = Weight of ice in accordance with Chapter 10 of ASCE 7. E ...
Building Code 2015 of Utah > 16 Structural Design > 1602 Definitions and Notations
Section 2102 Masonry, Definitions and Notations
WALL. Cavity wall. Dry-stacked, surface-bonded wall. Parapet wall. WYTHE. NOTATIONS. d b = Diameter ...
Building Code 2015 of Utah > 21 Masonry > 2102 Definitions and Notations
Section A402 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls, Definitions
Notwithstanding the applicable definitions, symbols and notations in the building code, the following definitions shall apply for the purposes ...
Existing Building Code 2015 of Utah > A4 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls > A402 Definitions
Section 1602 Structural Design, Notations
The following notations are used in this chapter: D = Dead load. D i = Weight of ice in accordance with Chapter 10 of ASCE 7. E ...
Building Code 2018 of Utah > 16 Structural Design > 1602 Notations
Section 2102 Masonry, Notations
The following notations are used in the chapter: NOTATIONS. d b = Diameter of reinforcement, inches (mm). F s = Allowable tensile ...
Building Code 2018 of Utah > 21 Masonry > 2102 Notations
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US