The loadbearing capacity of deep foundations discovered to have a sharp or sweeping bend shall be determined using an approved method of analysis by the engineer responsible for the deep foundation design in accordance with accepted engineering practice or by load testing a representative deep foundation.

Related Code Sections

1810.6.3 Soils and Foundations, Deep Foundations That Are Bent During Installation
The loadbearing capacity of deep foundations discovered to have a sharp or sweeping bend shall be determined using an approved method of analysis ...
1808.6.3 Soils and Foundations, Bent Piles
The load-bearing capacity of piles discovered to have a sharp or sweeping bend shall be determined using an approved method of analysis ...
1811.4.2 Soils and Foundations, Heaved Deep Foundations
Deep foundations that have heaved during the driving of adjacent deep foundations shall be redriven as necessary to develop the required capacity ...