Section G2432 (602) Decorative Vented Appliances for Installation in Fireplaces
JUMP TO FULL CODE CHAPTER
Decorative vented appliances for installation in approved solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and shall be installed in accordance with the manufacturer's installation instructions. Manually lighted natural gas decorative vented appliances shall be tested in accordance with ANSI Z21.84.
Decorative vented appliances for installation in approved solid fuel-burning fireplaces, with the exception of those tested in accordance with ANSI Z21.84, shall utilize a direct ignition device, an ignitor or a pilot flame to ignite the fuel at the main burner, and shall be equipped with a flame safeguard device. The flame safeguard device shall automatically shut off the fuel supply to a main burner or group of burners when the means of ignition of such burners becomes inoperative.
Decorative vented appliances for installation in fireplaces shall not be installed where prohibited by Section G2406.2.
Related Code Sections
Section G2432 Fuel Gas, (602) Decorative Vented Appliances for Installation in Fireplaces
Decorative vented appliances for installation in approved solid fuel burning fireplaces shall be tested in accordance with ANSI Z21.60 and shall ...
2010 Residential Code of NY > 24 Fuel Gas > G2432 (602) Decorative Vented Appliances for Installation in Fireplaces
Section 602 Specific Appliances, Decorative Vented Appliances for Installation in Fireplaces
Decorative vented appliances for installation in approved solid fuel-burning fireplaces shall be tested in accordance with ANSI Z21.60 and shall ...
2010 Fuel Gas Code of NY > 6 Specific Appliances > 602 Decorative Vented Appliances for Installation in Fireplaces
Section 602 Specific Appliances, Decorative Appliances for Installation in Fireplaces
Decorative appliances for installation in approved solid fuel-burning fireplaces shall be tested in accordance with ANSI Z21.60/CSA 6.26 and shall ...
2020 Fuel Gas Code of NYS > 6 Specific Appliances > 602 Decorative Appliances for Installation in Fireplaces
Section 602 Specific Appliances, (IFGC) Decorative Appliances for Installation in Fireplaces
Decorative appliances for installation in approved solid fuel-burning fireplaces shall be tested in accordance with ANSI Z21.60 and shall ...
Fuel Gas Code 2015 of New York State > 6 Specific Appliances > 602 (IFGC) Decorative Appliances for Installation in Fireplaces
601.2 Specific Appliances, Fireplaces
Z21.60 gas-log style unit) is installed in a vented solid fuel fireplace. Vented decorative gas fireplace appliances (ANSI Standard Z21.50 unit ...