2304.12.3.2 Decks, Fences, Patios, Planters, or Other Wooden Building Components
JUMP TO FULL CODE CHAPTER
Decks, fences, patios, planters, or other wooden building components that directly abut the sidewall of the foundation or structure shall be constructed so as to provide:
- Eighteen-inch (457 mm) clearance beneath or,
- Six-inch (152 mm) clearance between the top of the component and the exterior wall covering or,
- Have components that are easily removable by screws or hinges to allow access for inspection of the foundation sidewall and treatment for termites.
Related Code Sections
2304.11.4.3 Wood, Decks, Fences, Patios, Planters, or Other Wooden Building Components
Decks, fences, patios, planters, or other wooden building components that directly abut the sidewall of the foundation or structure shall ...
2014 FBC - Building, 5th edition > 23 Wood > 2304 General Construction Requirements > 2304.11 Protection Against Decay and Termites > 2304.11.4 Wood in Contact With the Ground or Fresh Water > 2304.11.4.3 Decks, Fences, Patios, Planters, or Other Wooden Building Components
2304.12.3.2 Wood, Decks, Fences, Patios, Planters, or Other Wooden Building Components
Decks, fences, patios, planters, or other wooden building components that directly abut the sidewall of the foundation or structure shall ...
2017 FBC - Building, 6th edition > 23 Wood > 2304 General Construction Requirements > 2304.12 Protection Against Decay and Termites > 2304.12.3 Wood in Contact With the Ground or Fresh Water > 2304.12.3.2 Decks, Fences, Patios, Planters, or Other Wooden Building Components
2304.12.3.2 Wood, Decks, Fences, Patios, Planters, or Other Wooden Building Components
Decks, fences, patios, planters, or other wooden building components that directly abut the sidewall of the foundation or structure shall ...
2020 FBC - Building, 7th edition > 23 Wood > 2304 General Construction Requirements > 2304.12 Protection Against Decay and Termites > 2304.12.3 Wood in Contact With the Ground or Fresh Water > 2304.12.3.2 Decks, Fences, Patios, Planters, or Other Wooden Building Components
2304.12 Wood, Protection Against Decay and Termites
Decks, fences, patios, planters, or other wooden building components that directly abut the sidewall of the foundation or structure ...
2020 FBC - Building, 7th edition > 23 Wood > 2304 General Construction Requirements > 2304.12 Protection Against Decay and Termites
454.1.3.1 Special Detailed Requirements Based on Use and Occupancy, Decks and Walkways
Pool wet decks shall be constructed of concrete or other nonabsorbent material having a smooth slip-resistant finish. Wet deck area finishes shall ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.3 Pool Appurtenances > 454.1.3.1 Decks and Walkways