1604.8.3 Decks
JUMP TO FULL CODE CHAPTER
Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads as applicable. Such attachment shall not be accomplished by the use of toenails or nails subject to withdrawal. Where positive connection to the primary building structure cannot be verified during inspection, decks shall be self-supporting. Connections of decks with cantilevered framing members to exterior walls or other framing members shall be designed for both of the following:
- The reactions resulting from the dead load and live load specified in Table 1607.1, or the snow load specified in Section 1608, in accordance with Section 1605, acting on all portions of the deck.
- The reactions resulting from the dead load and live load specified in Table 1607.1, or the snow load specified in Section 1608, in accordance with Section 1605, acting on the cantilevered portion of the deck, and no live load or snow load on the remaining portion of the deck.
Related Code Sections
1604.8.3 Structural Design, Decks
Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical ...
Building Code 2018 of Illinois > 16 Structural Design > 1604 General Design Requirements > 1604.8 Anchorage > 1604.8.3 Decks
1604.8.3 Structural Design, Decks
Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure ...
Building Code 2021 of Illinois > 16 Structural Design > 1604 General Design Requirements > 1604.8 Anchorage > 1604.8.3 Decks
1507.16.1 Roof Assemblies and Rooftop Structures, Deck Requirements
Photovoltaic shingles shall be applied to a solid or closely fitted deck, except where the shingles are specifically designed to be applied over ...
Building Code 2021 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.16 Photovoltaic Shingles > 1507.16.1 Deck Requirements
1507.17.1 Roof Assemblies and Rooftop Structures, Deck Requirements
Photovoltaic shingles shall be applied to a solid or closely fitted deck, except where the shingles are specifically designed to be applied over ...
Building Code 2018 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.17 Photovoltaic Shingles > 1507.17.1 Deck Requirements
1507.18.2 Roof Assemblies and Rooftop Structures, Deck Slope
BIPV roof panels shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater ...
Building Code 2018 of Illinois > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.18 Building-Integrated Photovoltaic Roof Panels > 1507.18.2 Deck Slope