• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R507.8.1 Deck Post to Deck Footing

Los Angeles Residential Code > 5 Floors > R507 Exterior Decks > R507.8 Deck Posts > R507.8.1 Deck Post to Deck Footing
JUMP TO FULL CODE CHAPTER

Posts shall bear on footings in accordance with Section R403 and Figure R507.8.1. Posts shall be restrained to prevent lateral displacement at the bottom support. Such lateral restraint shall be provided by manufactured connectors installed in accordance with Section R507 and the manufacturers' instructions or a minimum post embedment of 12 inches (305 mm) in surrounding soils or concrete piers.

FIGURE R507.8.1

TYPICAL DECK POSTS TO DECK FOOTINGS

Related Code Sections


R507.8.1 Floors, Deck Post to Deck Footing
Posts shall bear on footings in accordance with Section R403 and Figure R507.8.1. Posts shall be restrained to prevent lateral displacement ...
Los Angeles Residential Code > 5 Floors > R507 Exterior Decks > R507.8 Deck Posts > R507.8.1 Deck Post to Deck Footing
R507.4.1 Floors, Deck Post to Deck Footing Connection
Where posts bear on concrete footings in accordance with Section R403 and Figure R507.4.1, lateral restraint shall be provided by manufactured ...
Los Angeles Residential Code > 5 Floors > R507 Exterior Decks > R507.4 Deck Posts > R507.4.1 Deck Post to Deck Footing Connection
Section R507 Floors, Exterior Decks
on footings in accordance with Section R507.8.1. For SI: 1 inch = 25.4 mm. FIGURE R507.7.1 DECK BEAM TO DECK POST ...
Los Angeles Residential Code > 5 Floors > R507 Exterior Decks
Section R507 Floors, Exterior Decks
POSTS TO DECK FOOTING CONNECTION The minimum size ...
Los Angeles Residential Code > 5 Floors > R507 Exterior Decks
R507.3.2 Floors, Minimum Depth
Deck footings shall extend below the frost line specified in Table R301.2(1) in accordance with Section R403.1.4.1. Exceptions: Free-standing ...
Los Angeles Residential Code > 5 Floors > R507 Exterior Decks > R507.3 Footings > R507.3.2 Minimum Depth
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE