R507.5.1 Deck Beam Bearing
JUMP TO FULL CODE CHAPTER


The ends of beams shall have not less than 11/2 inches (38 mm) of bearing on wood or metal and not less than 3 inches (76 mm) of bearing on concrete or masonry for the entire width of the beam. Where multiple-span beams bear on intermediate posts, each ply must have full bearing on the post in accordance with Figures R507.5.1(1) and R507.5.1(2).
For SI: 1 inch = 25.4 mm.
DECK BEAM TO DECK POST
For SI: 1 inch = 25.4 mm.
NOTCHED POST-TO-BEAM CONNECTION
Related Code Sections
R507.5.1 Floors, Deck Beam Bearing
The ends of beams shall have not less than 1 1 / 2 inches (38 mm) of bearing on wood or metal and not less than 3 inches (76 mm) of bearing ...
2019 Residential Code of Ohio > 5 Floors > R507 Exterior Decks > R507.5 Deck Beams > R507.5.1 Deck Beam Bearing
R507.6 Floors, Deck Joists
mm) of bearing on concrete or masonry over its entire width. Joists bearing on top of a multiple-ply beam or ledger shall be fastened in accordance ...
1614.3.2.2 Structural Design, Beams
, girders, open web joist and joist girders support a concrete slab or concrete slab on metal deck that is attached to the beam or girder with not less ...
Ohio Building Code 2011 > 16 Structural Design > 1614 Structural Integrity > 1614.3 Frame Structures > 1614.3.2 Structural Steel, Open Web Steel Joist or Joist Girder, or Composite Steel and Concrete Frame Structures > 1614.3.2.2 Beams
1615.3.2.2 Structural Design, Beams
beams, girders, open web joist and joist girders support a concrete slab or concrete slab on metal deck that is attached to the beam or girder ...
Ohio Building Code 2017 > 16 Structural Design > 1615 Structural Integrity > 1615.3 Frame Structures > 1615.3.2 Structural Steel, Open Web Steel Joist or Joist Girder, or Composite Steel and Concrete Frame Structures > 1615.3.2.2 Beams
R606.6.3 Wall Construction, Beam Supports
Beams, girders or other concentrated loads supported by a wall or column shall have a bearing of not less than 3 inches (76 mm) in length measured ...
2019 Residential Code of Ohio > 6 Wall Construction > R606 General Masonry Construction > R606.6 Support Conditions > R606.6.3 Beam Supports