• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

6.4.3.1.2 Dead Band

2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.3 Controls and Diagnostics > 6.4.3.1 Zone Thermostatic Controls > 6.4.3.1.2 Dead Band
JUMP TO FULL CODE CHAPTER
Where used to control both heating and cooling, zone thermostatic controls shall be capable of and configured to provide a temperature range or dead band of at least 5°F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum.
Exceptions to 6.4.3.1.2
  1. Thermostats that require manual changeover between heating and cooling modes.
  2. Special occupancy or special applications where wide temperature ranges are not acceptable (such as retirement homes, process applications, museums, some areas of hospitals) and are approved by the authority having jurisdiction.

Related Code Sections


6.4.3.1.2 Heating, Ventilating, and Air Conditioning, Dead Band
Where used to control both heating and cooling, zone thermostatic controls shall be capable of and configured to provide a temperature range or dead ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.3 Controls and Diagnostics > 6.4.3.1 Zone Thermostatic Controls > 6.4.3.1.2 Dead Band
6.5.2.2 Heating, Ventilating, and Air Conditioning, Hydronic System Controls
both heated and chilled water are acceptable provided all of the following are met: The system is designed to allow a dead band between changeover ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.5 Prescriptive Compliance Path > 6.5.2 Simultaneous Heating and Cooling Limitation > 6.5.2.2 Hydronic System Controls
6.5.2 Heating, Ventilating, and Air Conditioning, Simultaneous Heating and Cooling Limitation
that comply with all of the following: The airflow rate in dead band between heating and cooling does not exceed the larger of the following: The ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.5 Prescriptive Compliance Path > 6.5.2 Simultaneous Heating and Cooling Limitation
6.4.3.6.1 Heating, Ventilating, and Air Conditioning, Dehumidification
controls are capable of and configured to maintain a dead band of at least 10% relative humidity where no active humidification or dehumidification ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.3 Controls and Diagnostics > 6.4.3.6 Humidification and Dehumidification Control > 6.4.3.6.1 Dehumidification
6.4.3.1 Heating, Ventilating, and Air Conditioning, Zone Thermostatic Controls
to control both heating and cooling, zone thermostatic controls shall be capable of and configured to provide a temperature range or dead band of at least 5°F ...
2021 Oregon Energy Efficiency Specialty Code (OEESC) > 6 Heating, Ventilating, and Air Conditioning > 6.4 Mandatory Provisions > 6.4.3 Controls and Diagnostics > 6.4.3.1 Zone Thermostatic Controls
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING