• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

466.10 Day Care Homes

2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 466 Day Care Occupancies > 466.10 Day Care Homes
JUMP TO FULL CODE CHAPTER

466.10.1

This section establishes life safety requirements for day care homes in which more than three but not more than 12 clients receive care, maintenance and supervision by other than their relative(s) or legal guardian(s) for less than 24 hours per day.

Exception: Facilities that supervise clients on a temporary basis with a parent or guardian in close proximity.

466.10.2 Definitions

For definitions, see Chapter 2.

466.10.3

Places of religious worship shall not be required to meet the provisions of this section in order to operate a nursery while services are being held in the building.

466.10.4

Occupancies that include part-day preschools, kindergartens and other schools whose purpose is primarily educational even though the children are of preschool age shall comply with the provisions for Group E occupancy.

466.10.5 Smoke Detection Systems

466.10.5.1

Single-station smoke alarms installed in accordance with the household fire warning equipment requirements of Chapter 2 of NFPA 72 shall be installed within day care homes.

Exception: System smoke detectors installed in accordance with NFPA 72 and arranged to function in the same manner shall be permitted.

466.10.5.2

Where the day care home is located within a building of another occupancy, any corridors serving the day care home shall be provided with a complete smoke detection system installed in accordance with NFPA 72.

466.10.5.3

Single-station smoke alarms shall be powered by the building electrical system.

466.10.5.4

Single-station smoke alarms shall be provided in all rooms used for sleeping.

466.10.5.5

Where two or more smoke alarms are required within a living unit, suite of rooms, or similar area, they shall be arranged so that operation of any smoke alarm shall cause all smoke alarms within the living unit, suite of rooms or similar area to sound.

466.10.5.5.1

The alarms shall sound only within an individual living unit, suite of rooms or similar area and shall not actuate the building fire alarm system. Remote annunciation shall be permitted.

Related Code Sections


466.10 Special Detailed Requirements Based on Use and Occupancy, Day Care Homes
This section establishes life safety requirements for day care homes in which more than three but not more than 12 clients receive care, maintenance ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 466 Daycare Occupancies > 466.10 Day Care Homes
466.10 Special Detailed Requirements Based on Use and Occupancy, Day Care Homes
This section establishes life safety requirements for day care homes in which more than three but not more than 12 clients receive care, maintenance ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 466 Day Care Occupancies > 466.10 Day Care Homes
466.10 Special Detailed Requirements Based on Occupancy and Use, Day Care Homes
This section establishes life safety requirements for day care homes in which more than three but not more than 12 clients receive care, maintenance ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 466 Day Care Occupancies > 466.10 Day Care Homes
466.10.2 Special Detailed Requirements Based on Occupancy and Use, Definitions
For definitions, see Chapter 2 ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 466 Day Care Occupancies > 466.10 Day Care Homes > 466.10.2 Definitions
466.10.3 Special Detailed Requirements Based on Use and Occupancy,
Places of religious worship shall not be required to meet the provisions of this section in order to operate a nursery while services are being held ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 466 Day Care Occupancies > 466.10 Day Care Homes > 466.10.3
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE