1808.5.5 Damage to Adjacent Structures or Piles
JUMP TO FULL CODE CHAPTER
Piles shall be installed in such a manner and sequence as to prevent distortion or damage that affects the structural integrity of the piles being installed, or previously installed adjacent piles. The sequence of the installation shall avoid compacting the surrounding soil to the extent that other piles cannot be installed properly, and shall prevent ground movements that are capable of damaging adjacent structures. Piles shall be installed with adequate provision for the protection of adjacent buildings and property.
Related Code Sections
1808.5.5 Soils and Foundations, Damage to Adjacent Structures or Piles
piles cannot be installed properly, and shall prevent ground movements that are capable of damaging adjacent structures. Piles shall be installed ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.5 Installation > 1808.5.5 Damage to Adjacent Structures or Piles
1808.2.14 Soils and Foundations, Installation Sequence
, and to prevent ground movements that are capable of damaging adjacent structures ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.14 Installation Sequence
§27-696 Foundations, General Requirements for Installation of Piles
(a) Protection of adjacent property. Piles shall be installed with adequate provision for the protection of adjacent buildings and property. (b ...
NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-696 General Requirements for Installation of Piles
3309.6 Safeguards During Construction or Demolition, Foundation Operations Affecting Adjacent Properties
of the adjacent foundations shall be investigated and provision shall be made to prevent damage to such buildings. When ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.6 Foundation Operations Affecting Adjacent Properties
Article 9 Foundations, Pile Driving Operations
adjacent structures. Jetting or augering shall be stopped at least three feet above the final expected pile-tip elevation and at least three feet ...