[BS] 302.5.2 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
JUMP TO FULL CODE CHAPTER
Flanges and lips of load-bearing cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing cold-formed steel framing members shall be permitted along the centerline of the web of the framing member and shall not exceed the dimensional limitations, penetration spacing or minimum hole edge distance as prescribed by the registered design professional. Cutting, notching and boring holes of steel floor/roof decking shall be as prescribed by the registered design professional.
Related Code Sections
C101.5 Structural Safety, Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
Flanges and lips of load-bearing cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing cold-formed steel ...
Plumbing Code 2018 of Colorado > C Structural Safety > C101 Cutting, Notching and Boring in Wood Members > C101.5 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
302.5.2 General Regulations, Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
Flanges and lips of load-bearing cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing cold-formed steel ...
Mechanical Code 2018 of Colorado > 3 General Regulations > 302 Protection of Structure > 302.5 Cutting, Notching and Boring in Steel Framing > 302.5.2 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
302.5.2 General Regulations, Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
Flanges and lips of load-bearing cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing cold-formed steel ...
Mechanical Code 2015 of Colorado > 3 General Regulations > 302 Protection of Structure > 302.5 Cutting, Notching and Boring in Steel Framing > 302.5.2 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
302.5.2 General Regulations, Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
Flanges and lips of load-bearing cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing cold-formed steel ...
Mechanical Code 2021 of Colorado > 3 General Regulations > 302 Protection of Structure > 302.5 Cutting, Notching and Boring in Steel Framing > 302.5.2 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
302.6 General Regulations, Cutting, Notching and Boring Holes in Cold-Formed Steel Framing
Flanges and lips of load-bearing, cold-formed steel framing members shall not be cut or notched. Holes in webs of load-bearing, cold-formed steel ...
Fuel Gas Code 2018 of Colorado > 3 General Regulations > 302 (IFGC) Structural Safety > 302.6 Cutting, Notching and Boring Holes in Cold-Formed Steel Framing