• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

715.1.1 Curtain Wall Assembly

2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 715 Fire-Resistant Joint Systems > 715.1 General > 715.1.1 Curtain Wall Assembly
JUMP TO FULL CODE CHAPTER
The void created at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be protected in accordance with Section 715.4.

Related Code Sections


715.1.1 Fire and Smoke Protection Features, Curtain Wall Assembly
The void created at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be protected in accordance with Section ...
2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 715 Fire-Resistant Joint Systems > 715.1 General > 715.1.1 Curtain Wall Assembly
705.9.1 Fire and Smoke Protection Features, Voids
The void created at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be protected in accordance with Section ...
2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 705 Exterior Walls > 705.9 Joints > 705.9.1 Voids
712.1.5.1 Fire and Smoke Protection Features, Joints in or Between Horizontal Assemblies
and an exterior curtain wall assembly shall be permitted where protected in accordance with Section 715.4 ...
2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.5 Joints > 712.1.5.1 Joints in or Between Horizontal Assemblies
715.4.2 Fire and Smoke Protection Features, Exterior Curtain Wall/Vertical Fire Barrier Intersections
Voids created at the intersection of nonfire-resistance-rated exterior curtain wall assemblies and fire barriers shall be filled. An approved ...
2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 715 Fire-Resistant Joint Systems > 715.4 Exterior Curtain Wall/Floor Intersection > 715.4.2 Exterior Curtain Wall/Vertical Fire Barrier Intersections
712.1.5 Fire and Smoke Protection Features, Joints
at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be permitted where protected in accordance with Section 715.4 ...
2018 Philadelphia Building Code > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.5 Joints
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE