// CODE SNIPPET
1926.1003(e) Crush Test Procedure
JUMP TO FULL CODE CHAPTER
The same frame shall be subjected to the crush test following the drop test and static or dynamic test.
The test load shall be applied as shown in Figure W-27, with the seat positioned as specified in 29 CFR 1926.1002(d)(4). Loading cylinders shall be mounted pivotally at both ends. Loads applied by each cylinder shall be equal within two percent, and the sum of the loads of the two cylinders shall be two times the tractor weight as set forth in 29 CFR 1926.1002(e)(1). The maximum width of the beam illustrated in Figure W-27 shall be 6 in. (152 mm).
Related Code Sections
1926.1003(e) Rollover Protective Structures; Overhead Protection, Crush Test Procedure
The same frame shall be subjected to the crush test following the drop test and static or dynamic test ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(e) Crush Test Procedure
1926.1001(e) Rollover Protective Structures; Overhead Protection, Test Procedure
The test procedure shall include the following, in the sequence indicated ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors > 1926.1001(e) Test Procedure
1926.1002(g)(2) Rollover Protective Structures; Overhead Protection, Test Procedure
The test procedure shall be repeated on the same frame using L (rear ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(2) Test Procedure
1926.1430(e) Cranes & Derricks in Construction, Crush/Pinch Points
The employer must train each employee who works with the equipment to keep clear of holes, and crush/pinch points and the hazards addressed ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1430 Training > 1926.1430(e) Crush/Pinch Points
1926.1002(f) Rollover Protective Structures; Overhead Protection, Other Test Procedures
When the field-upset test is not used to determine ROPS performance, either the static test or the dynamic test, contained in paragraph (g) or (h ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(f) Other Test Procedures