• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.1001(j)(8) Criteria to Rebut the Designation of Installed Material as PACM

OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(j) Communication of Hazards to Employees -- Introduction > 1910.1001(j)(8) Criteria to Rebut the Designation of Installed Material as PACM
JUMP TO FULL CODE CHAPTER

1910.1001(j)(8)(i)

At any time, an employer and/or building owner may demonstrate, for purposes of this standard, that PACM does not contain asbestos. Building owners and/or employers are not required to communicate information about the presence of building material for which such a demonstration pursuant to the requirements of paragraph (j)(8)(ii) of this section has been made. However, in all such cases, the information, data and analysis supporting the determination that PACM does not contain asbestos, shall be retained pursuant to paragraph (m) of this section.

1910.1001(j)(8)(iii)

The employer and/or building owner may demonstrate that flooring material including associated mastic and backing does not contain asbestos, by a determination of an industrial hygienist based upon recognized analytical techniques showing that the material is not ACM.

1910.1001(j)(8)(ii)

An employer or owner may demonstrate that PACM does not contain asbestos by the following:

1910.1001(j)(8)(ii)(A)

Having a completed inspection conducted pursuant to the requirements of AHERA (40 CFR 763, Subpart E) which demonstrates that no ACM is present in the material; or

1910.1001(j)(8)(ii)(B)

Performing tests of the material containing PACM which demonstrate that no ACM is present in the material. Such tests shall include analysis of bulk samples collected in the manner described in 40 CFR 763.86. The tests, evaluation and sample collection shall be conducted by an accredited inspector or by a CIH. Analysis of samples shall be performed by persons or laboratories with proficiency demonstrated by current successful participation in a nationally recognized testing program such as the National Voluntary Laboratory Accreditation Program (NVLAP) or the National Institute for Standards and Technology (NIST) or the Round Robin for bulk samples administered by the American Industrial Hygiene Association (AIHA) or an equivalent nationally-recognized round robin testing program.

Related Code Sections


1910.1001(j)(8) Toxic and Hazardous Substances, Criteria to Rebut the Designation of Installed Material as PACM
of the material containing PACM which demonstrate that no ACM is present in the material. Such tests shall include analysis of bulk samples collected ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(j) Communication of Hazards to Employees -- Introduction > 1910.1001(j)(8) Criteria to Rebut the Designation of Installed Material as PACM
1910.1001(j)(2) Toxic and Hazardous Substances, Installed Asbestos Containing Material
no later than 1980 for purposes of this standard. These materials are designated "presumed ACM or PACM", and are defined in paragraph (b ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(j) Communication of Hazards to Employees -- Introduction > 1910.1001(j)(2) Installed Asbestos Containing Material
1910.1001(b) Toxic and Hazardous Substances, Definitions
of a material as "PACM" may be rebutted pursuant to paragraph (j)(8) of this section. Regulated area means an area established by the employer ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(b) Definitions
1910.1001(j)(5)(i) Toxic and Hazardous Substances, Labeling
When a building owner or employer identifies previously installed ACM and/or PACM, labels or signs shall be affixed or posted so that employees ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(j) Communication of Hazards to Employees -- Introduction > 1910.1001(j)(5) Warning Labels > 1910.1001(j)(5)(i) Labeling
1910.1001(j) Toxic and Hazardous Substances, Communication of Hazards to Employees -- Introduction
no later than 1980 for purposes of this standard. These materials are designated "presumed ACM or PACM", and are defined in paragraph (b ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1001 Asbestos > 1910.1001(j) Communication of Hazards to Employees -- Introduction
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING