R602.10.9.1 Cripple Wall Bracing in Seismic Design Categories D
JUMP TO FULL CODE CHAPTER
0, D1 and D2. In addition to the requirements of Section R602.10.9, where braced wall lines at interior walls occur without a continuous foundation below, the length of parallel exterior cripple wall bracing shall be 11/2 times the length required by Tables R602.10.1.2(1) and R602.10.1.2(2). Where cripple walls braced using Method WSP of Section R602.10.2 cannot provide this additional length, the capacity of the sheathing shall be increased by reducing the spacing of fasteners along the perimeter of each piece of sheathing to 4 inches (102 mm) on center.
In Seismic Design Category D2, cripple walls shall be braced in accordance with Tables R602.10.1.2(1) and R602.10.1.2(2).
Related Code Sections
R602.10.9.1 Wall Construction, Cripple Wall Bracing in Seismic Design Categories D
Design Category D 2 , cripple walls shall be braced in accordance with Tables R602.10.1.2(1) and R602.10.1.2(2) ...
Residential Code 2009 of Tennessee > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.9 Cripple Wall Bracing > R602.10.9.1 Cripple Wall Bracing in Seismic Design Categories D
2308.9.4.1 Wood, Bracing
For the purposes of this section, cripple walls having a stud height exceeding 14 inches (356 mm) in structures assigned to Seismic Design Category ...
Building Code 2012 of Tennessee > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.9 Wall Framing > 2308.9.4 Cripple Walls > 2308.9.4.1 Bracing
R602.10.10 Wall Construction, Cripple Wall Bracing
In Seismic Design Category D 2 , cripple walls shall ...
Residential Code 2018 of Tennessee > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.10 Cripple Wall Bracing
R602.10.7.1 Wall Construction, Braced Wall Panel Support for Seismic Design Category D
2 . In one-story buildings located in Seismic Design Category D 2 , braced wall panels shall be supported on continuous foundations at intervals ...
Residential Code 2009 of Tennessee > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.7 Braced Wall Panel Support > R602.10.7.1 Braced Wall Panel Support for Seismic Design Category D
R403.1.2 Foundations, Continuous footing in Seismic Design Categories D0, D1 and D2
in Seismic Design Category D 2 , in which all braced wall panels , interior and exterior, shall be supported on continuous foundations. Exception: Two ...
Residential Code 2018 of Tennessee > 4 Foundations > R403 Footings > R403.1 General > R403.1.2 Continuous footing in Seismic Design Categories D0, D1 and D2