Where a crawl space is at or below grade level, all 125-volt, single-phase, 15- and 20-ampere receptacles installed in such spaces shall have ground-fault circuit-interrupter protection for personnel.

Related Code Sections

E3902.4 Power and Lighting Distribution, Crawl Space Receptacles
Where a crawl space is at or below grade level, all 125-volt, single-phase, 15- and 20-ampere receptacles installed in such spaces shall have ground ...
1208.1 Interior Environment, Crawl Spaces
Crawl spaces shall be provided with not less than one access opening that shall be not less than 18 inches by 24 inches (457 mm by 610 mm) ...
1209.1 Interior Environment, Crawl Spaces
Crawl spaces shall be provided with no fewer than one access opening which shall be not less than 18 inches by 24 inches (457 mm by 610 mm) ...
R316.5.4 Building Planning, Crawl Spaces
The thermal barrier specified in Section R316.4 is not required where all of the following apply: Crawlspace access is required by Section R408.4 ...