227.3 Counters
JUMP TO FULL CODE CHAPTER
Where provided, at least one of each type of sales counter and service counter shall comply with 904.4. Where counters are dispersed throughout the building or facility, counters complying with 904.4 also shall be dispersed.
Advisory 227.3 Counters. Types of counters that provide different services in the same facility include, but are not limited to, order, pick-up, express, and returns. One continuous counter can be used to provide different types of service. For example, order and pick-up are different services. It would not be acceptable to provide access only to the part of the counter where orders are taken when orders are picked-up at a different location on the same counter. Both the order and pick-up section of the counter must be accessible.
Related Code Sections
227.3 Scoping Requirements, Counters
Where provided, at least one of each type of sales counter and service counter shall comply with 904.4. Where counters are dispersed throughout ...
904.3.2 Built-In Elements, Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground. The top of the counter edge protection shall ...
2010 ADA Standards > 9 Built-In Elements > 904 Check-Out Aisles and Sales and Service Counters > 904.3 Check-Out Aisles > 904.3.2 Counter
231.4.1 Scoping Requirements, Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides. Where counters are provided ...
2010 ADA Standards > 2 Scoping Requirements > 231 Judicial Facilities > 231.4 Visiting Areas > 231.4.1 Cubicles and Counters
232.5.1 Scoping Requirements, Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides. Where counters are provided ...
2010 ADA Standards > 2 Scoping Requirements > 232 Detention Facilities and Correctional Facilities > 232.5 Visiting Areas > 232.5.1 Cubicles and Counters
406.2 Accessible Routes, Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20. The adjacent ...