Countertops that contain sinks and cooking units shall provide a minimum of 15 inches (15" = 381mm) of clear countertop on at least one side of the cooking unit and on at least one side of the sink and shall have a clear space underneath that complies with 521 CMR 32.6, Kneespace. Countertops shall be mounted no higher than 34 inches (34" = 864mm) above the finish floor. See Fig. 32a.

Knee Space under Counter Tops
Figure 32a

Related Code Sections

32.2 Kitchens, Counter Tops
be mounted no higher than 34 inches (34" = 864mm) above the finish floor. See Fig. 32a. Knee Space under Counter Tops Figure 32a  ...
(F) Equipment for General Use, Receptacles in Work Surfaces
Receptacle assemblies and GFCI receptacle assemblies listed for work surface or counter-top applications shall be permitted to be installed in work ...
17.2.5 Restaurants,
Height of Tables or Counters: The tops of accessible tables and counters shall be from 28 inches to 34 inches (28" to 34" = 711mm to 864mm) above ...
105.2 Scope and Administration, Work Exempt From Permit
of people or uses other than normally expected for this purpose. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish ...