P-809.7 Corrosive Soils
JUMP TO FULL CODE CHAPTER
When used underground in corrosive soil, all metallic pipe and fittings shall be tar enamel
coated or protected in an equivalent approved manner against external corrosion.
Related Code Sections
P-809.7 Water Supply and Distribution, Corrosive Soils
When used underground in corrosive soil, all metallic pipe and fittings shall be tar enamel
coated or protected in an equivalent approved manner ...
Philadelphia Plumbing Code > 8 Water Supply and Distribution > P-809 Material for Water Pipe, Tubing and Fittings > P-809.7 Corrosive Soils
P2603.3 General Plumbing Requirements, Protection Against Corrosion
or masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact ...
2018 Philadelphia Residential Code > 26 General Plumbing Requirements > P2603 Structural and Piping Protection > P2603.3 Protection Against Corrosion
305.1 General Regulations, Protection Against Contact
or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used ...
Plumbing Code 2018 of Philadelphia > 3 General Regulations > 305 Protection of Pipes and Plumbing System Components > 305.1 Protection Against Contact
G2415.11 Fuel Gas, (404.11) Protection Against Corrosion
Metallic pipe or tubing exposed to corrosive action, such as soil condition or moisture, shall be protected in an approved manner. Zinc coatings ...
2018 Philadelphia Residential Code > 24 Fuel Gas > G2415 (404) Piping System Installation > G2415.11 (404.11) Protection Against Corrosion
404.11 Gas Piping Installations, Protection Against Corrosion
Steel pipe or tubing exposed to corrosive action, such as soil conditions or moisture, shall be protected in accordance Sections 404.11.1 through ...
2018 Philadelphia Fuel Gas Code > 4 Gas Piping Installations > 404 (IFGC) Piping System Installation > 404.11 Protection Against Corrosion