• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1812.2.1 Corrosion Testing Requirements

NYC Building Code 2014 > 18 Soils and Foundations > 1812 Helical Piles > 1812.2 Design > 1812.2.1 Corrosion Testing Requirements
JUMP TO FULL CODE CHAPTER
Tests shall be performed in each soil layer for soil resistivity, soil pH, organic content and sulphate concentration. The device or system shall not be used in conditions that are indicative of a potential pile corrosion situation, as defined by soil resistivity less than 1,000 ohm-cm, pH less than 5.5, soils with high organic content, sulfate concentrations greater than 1,000 ppm, landfills, or mine waste.

Related Code Sections


1812.2.1 Soils and Foundations, Corrosion Testing Requirements
Tests shall be performed in each soil layer for soil resistivity, soil pH, organic content and sulphate concentration. The device or system shall ...
NYC Building Code 2014 > 18 Soils and Foundations > 1812 Helical Piles > 1812.2 Design > 1812.2.1 Corrosion Testing Requirements
1904.4 Concrete, Corrosion Protection of Reinforcement
ion content, test procedures shall conform to ASTM C 1218. TABLE 1904.4.1 MAXIMUM CHLORIDE ION CONTENT FOR CORROSION PROTECTION OF ...
NYC Building Code 2008 > 19 Concrete > 1904 Durability Requirements > 1904.4 Corrosion Protection of Reinforcement
502.9.2 Exhaust Systems, Corrosives
Where corrosive materials in amounts exceeding the maximum allowable quantity per control area are dispensed or used, mechanical exhaust ventilation ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 502 Required Systems > 502.9 Hazardous Materials—Requirements for Specific Materials > 502.9.2 Corrosives
502.9.2 Exhaust Systems, Corrosives
Where corrosive materials in amounts exceeding the maximum allowable quantity per control area are dispensed or used, mechanical exhaust ventilation ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 502 Required Systems > 502.9 Hazardous Materials—Requirements for Specific Materials > 502.9.2 Corrosives
Article 9 Construction [PDF] (page 60)
which have been machine finished. 6. Surfaces of structural steels meeting the specifications for atmospheric corrosion resistant steel shown by test ...
NYC 1938 Code [PDF] > 9 Construction
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE