Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

625.17 Cords and Cables

National Electrical Code 2020 of Minnesota > 6 Special Equipment > 625 Electric Vehicle Power Transfer System > 625.17 Cords and Cables
JUMP TO FULL CODE CHAPTER

(A) Power-Supply Cord

The cable for cord-connected equipment shall comply with all of the following:
  1. Be any of the types specified in 625.17(B)(1) or hard service cord, junior hard service cord, or portable power cable types in accordance with Table 400.4. Hard service cord, junior hard service cord, or portable power cable types shall be listed, as applicable, for exposure to oil and damp and wet locations.
  2. Have an ampacity as specified in Table 400.5(A)(1) or, for 8 AWG and larger, in the 60°C columns of Table 400.5(A)(2).
  3. Have an overall length as specified in either of the following:
    1. When the interrupting device of the personnel protection system specified in 625.22 is located within the enclosure of the supply equipment or charging system, the power-supply cord shall be not more than the length indicated in (i) or (ii):
      1. For portable equipment in accordance with 625.44(A), the power supply cord shall be not more than 300 mm (12 in.) long.
      2. For stationary equipment in accordance with 625.44(B), the power supply cord shall be not more than 1.8 m (6 ft) long and the equipment shall be installed at a height that prevents the power supply cord from contacting the floor when it is connected to the proper receptacle.
    2. When the interrupting device of the personnel protection system specified in 625.22 is located at the attachment plug, or within the first 300 mm (12 in.) of the power-supply cord, the overall cord length shall be not greater than 4.6 m (15 ft).

(B) Output Cable to Electric Vehicle

The output cable to the electric vehicle shall be one of the following:
  1. Listed Type EV, EVJ, EVE, EVJE, EVT, or EVJT flexible cable as specified in Table 400.4
  2. An integral part of listed electric vehicle supply equipment
Informational Note: For information and listing requirements for electric vehicle supply equipment, see UL 2594-2016, Standard for Electric Vehicle Supply Equipment, and UL 2202-2009, Standard for Electric Vehicle (EV) Charging System Equipment.

(C) Overall Cord and Cable Length

The overall usable length shall not exceed 7.5 m (25 ft) unless equipped with a cable management system that is part of the listed electric vehicle supply equipment.

(1) Portable Equipment

For portable EVSE, the cord-exposed usable length shall be measured from the face of the attachment plug to the face of the electric vehicle connector.

(2) Fastened in Place

Where the electric vehicle supply equipment is fastened in place, the usable length of the output cable shall be measured from the cable exit of the electric vehicle supply equipment to the face of the electric vehicle connector.

(D) Interconnecting Cabling Systems

Other cabling systems that are integral parts of listed EVSE and are intended to interconnect pieces of equipment within an EVSE system using approved installation methods shall be permitted.

Related Code Sections


625.17 Special Equipment, Cords and Cables
The cable for cord-connected equipment shall comply with all of the following: Be any of the types specified in 625.17(B)(1) or hard service cord ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 625 Electric Vehicle Power Transfer System > 625.17 Cords and Cables
(B) Wiring Methods and Materials, Cord and Cable Assemblies
Suitable cord and cable assemblies identified for extra-hard usage or hard usage and listed bus drop cable shall be permitted as branches from ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 368 Busways > 368.56 Branches From Busways > (B) Cord and Cable Assemblies
(C) Special Equipment, Flexible Cords and Cables
Flexible cords and cables shall comply with Article 400 and be identified as extra hard usage, rated for outdoor use, and water and sunlight ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 600 Electric Signs and Outline Lighting > 600.34 Photovoltaic (PV) Powered Sign > (C) Flexible Cords and Cables
(3) Special Equipment, Flexible Cords and Cables
Flexible cords and cables that are components of listed equipment and used in circuits operating at 30 volts rms or less or 42 volts dc or less shall ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.21 Wiring Methods > (C) Platform Lifts and Stairway Chairlift Raceways > (3) Flexible Cords and Cables
(B) Special Equipment, Flexible Cords and Cables
Flexible cords and cables, where used to connect the moving parts of turbines or where used for ready removal for maintenance and repair, shall ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 694 Wind Electric Systems > 694.30 Permitted Methods > (B) Flexible Cords and Cables
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING