Masonry chimneys shall not be corbeled more than half of the chimney's wall thickness from a wall or foundation, nor shall a chimney be corbeled from a wall or foundation that is less than 12 inches (305 mm) in thickness unless it projects equally on each side of the wall, except that on the second story of a two-story dwelling, corbeling of chimneys on the exterior of the enclosing walls is permitted to equal the wall thickness. The projection of a single course shall not exceed one-half the unit height or one-third of the unit bed depth, whichever is less.

Related Code Sections

2113.5 Masonry, Corbeling
Masonry chimneys shall not be corbeled more than half of the chimney's wall thickness from a wall or foundation, nor shall a chimney be corbeled from ...
2113.5 Masonry, Corbeling
Masonry chimneys shall not be corbeled more than half of the chimney's wall thickness from a wall or foundation, nor shall a chimney be corbeled from ...
16.5 Connections Between Members, Brackets and Corbels
Brackets and corbels with shear span-to-depth ratio av/d ≤ 1.0 and with factored horizontal tensile force Nuc ≤ Vu shall be permitted to be designed ...
16.5 Connections Between Members, Brackets and Corbels
Brackets and corbels with shear span-to-depth ratio av/d ≤ 1.0 and with factored restraint force Nuc ≤ Vu shall be permitted to be designed ...
16.5.3 Connections Between Members, Required Strength
The section at the face of the support shall be designed to resist simultaneously the factored shear Vu, the factored restraint force Nuc ...