• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P3003.10 Copper Pipe

Residential Code 2012 of South Holland > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.10 Copper Pipe
JUMP TO FULL CODE CHAPTER
Joints between copper or copper-alloy pipe or fittings shall comply with Sections P3003.10.1 through P3003.10.4.

P3003.10.1 Brazed Joints

All joint surfaces shall be cleaned. An approved flux shall be applied where required. The joint shall be brazed with a filler metal conforming to AWS A5.8.

P3003.10.2 Mechanical Joints

Mechanical joints shall be installed in accordance with the manufacturer's instructions.

P3003.10.3 Soldered Joints

Solder joints shall be made in accordance with the methods of ASTM B 828. All cut tube ends shall be reamed to the full inside diameter of the tube end. All joint surfaces shall be cleaned. A flux conforming to ASTM B 813 shall be applied. The joint shall be soldered with a solder conforming to ASTM B 32.

P3003.10.4 Threaded Joints

Threads shall conform to ASME B1.20.1. Pipe-joint compound or tape shall be applied on the male threads only.

Related Code Sections


P3003.10 Sanitary Drainage, Copper Pipe
Joints between copper or copper-alloy pipe or fittings shall comply with Sections P3003.10.1 through P3003.10.4 ...
Residential Code 2012 of South Holland > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.10 Copper Pipe
P3003.13.2 Sanitary Drainage, Copper Pipe or Tubing to Galvanized Steel Pipe
Joints between copper pipe or tubing and galvanized steel pipe shall be made with a copper-alloy or dielectric fitting. The copper tubing shall ...
Residential Code 2018 of South Holland > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.13 Joints Between Different Materials > P3003.13.2 Copper Pipe or Tubing to Galvanized Steel Pipe
1107.5.2 Refrigeration, Copper and Copper-Alloy Pipe
Standard iron-pipe size, copper and copper-alloy (not less than 80-percent copper) pipe shall conform to ASTM B42 and ASTM B43 ...
Mechanical Code 2018 of South Holland > 11 Refrigeration > 1107 Refrigerant Piping > 1107.5 Materials for Refrigerant Pipe and Tubing > 1107.5.2 Copper and Copper-Alloy Pipe
1203.5 Hydronic Piping, Copper or Copper-Alloy Pipe
Joints between copper or copper-alloy pipe or fittings shall be brazed, mechanical, soldered, threaded or welded joints conforming to Section 1203.3 ...
Mechanical Code 2018 of South Holland > 12 Hydronic Piping > 1203 Joints and Connections > 1203.5 Copper or Copper-Alloy Pipe
1203.7 Hydronic Piping, Copper or Copper-Alloy Pipe
Joints between copper or copper-alloy pipe or fittings shall be brazed, mechanical, soldered, threaded or welded joints conforming to Section 1203.3 ...
Mechanical Code 2012 of South Holland > 12 Hydronic Piping > 1203 Joints and Connections > 1203.7 Copper or Copper-Alloy Pipe
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING