705.10.2 Copper or Copper Alloy Pipe to Threaded Pipe Joints
JUMP TO FULL CODE CHAPTER
Joints from copper or copper alloy pipe or tubing to threaded pipe shall be made by the use of a listed copper alloy adapter or dielectric fitting. The joint between the copper or copper alloy pipe and the fitting shall be a soldered or brazed, and the connection between the threaded and the fittings shall be made with a standard pipe size threaded joint.
Related Code Sections
705.10.2 Sanitary Drainage, Copper or Copper Alloy Pipe to Threaded Pipe Joints
Joints from copper or copper alloy pipe or tubing to threaded pipe shall be made by the use of a listed copper alloy adapter or dielectric fitting ...
Uniform Plumbing Code 2018 of Nevada > 7 Sanitary Drainage > 705.0 Joints and Connections > 705.10 Joints Between Various Materials > 705.10.2 Copper or Copper Alloy Pipe to Threaded Pipe Joints
605.16.1 Water Supply and Distribution, Copper or Copper Alloy Pipe or Tubing to Threaded Pipe Joints
Joints from copper or copper alloy pipe or tubing to threaded pipe shall be made using copper alloy adapter, copper alloy nipple [minimum 6 inches ...
Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 605.0 Joints and Connections > 605.16 Joints Between Various Materials > 605.16.1 Copper or Copper Alloy Pipe or Tubing to Threaded Pipe Joints
1211.14.1 Hydronics, Copper or Copper Alloy Pipe or Tubing to Threaded Pipe Joints
Joints from copper or copper alloy pipe or tubing to threaded pipe shall be made by the use of copper alloy adapter, copper alloy nipple [minimum 6 ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1211.0 Joints and Connections > 1211.14 Joints Between Various Materials > 1211.14.1 Copper or Copper Alloy Pipe or Tubing to Threaded Pipe Joints
1109.2 Refrigeration, Joints
corrosion inhibitor. Copper or copper alloy pipe joints of iron pipe size shall be of approved threaded, flanged, press-connect or brazed types. Copper ...
Uniform Mechanical Code 2018 of Nevada > 11 Refrigeration > 1109.0 Refrigeration Piping, Containers, and Valves > 1109.2 Joints
705.3 Sanitary Drainage, Copper or Copper Alloy Pipe (DWV) and Joints
Threaded joints for copper or copper alloy pipe shall be made with pipe threads that comply ...
Uniform Plumbing Code 2018 of Nevada > 7 Sanitary Drainage > 705.0 Joints and Connections > 705.3 Copper or Copper Alloy Pipe (DWV) and Joints