420.11.1 Cooking Appliances
Go To Full Code Chapter
Where located in Group R-2 college dormitories, domestic cooking appliances for use by residents shall be in compliance with all of the following:
- The types of domestic cooking appliances shall be limited to ovens, cooktops, ranges, warmers, coffee makers and microwaves.
- Domestic cooking appliances shall be limited to approved locations.
- Cooktops and ranges shall be protected in accordance with Section 904.14.
- Cooktops and ranges shall be provided with a domestic cooking hood installed and constructed in accordance with Section 505 of the International Mechanical Code.
Upcodes Diagrams
Related Code Sections
420.10.1 Special Detailed Requirements Based on Occupancy and Use, Cooking Appliances
Where located in Group R-2 college dormitories, domestic cooking appliances for use by residents shall be in compliance with all of the following ...
420.11.1 Special Detailed Requirements Based on Occupancy and Use, Cooking Appliances
Where located in Group R-2 college dormitories, domestic cooking appliances for use by residents shall be in compliance with all of the following ...
Section 917 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Cooking Appliances
Cooking appliances that are designed for permanent installation, including ranges, ovens, stoves, broilers, grills, fryers, griddles and barbecues ...
407.2.7 Special Detailed Requirements Based on Occupancy and Use, Domestic Cooking Appliances
In Group I-2 occupancies, installation of cooking appliances used in domestic cooking facilities shall comply with all of the following: The types ...
(3) Wiring and Protection, Household Ranges and Cooking Appliances
Branch-circuit conductors supplying household ranges, wall-mounted ovens, counter-mounted cooking units, and other household cooking appliances shall ...