• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 1110 Controlled Flow Roof Drain Systems

Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1110 Controlled Flow Roof Drain Systems
JUMP TO FULL CODE CHAPTER

1110.1 General

The roof of a structure shall be designed for the storage of water where the storm drainage system is engineered for controlled flow. The controlled flow roof drain system shall be an engineered system in accordance with this section and the design, submittal, approval, inspection and testing requirements of Section 316.1. The controlled flow system shall be designed based on the required rainfall rate in accordance with Section 1106.1.

1110.2 Control Devices

The control devices shall be installed so that the rate of discharge of water per minute shall not exceed the values for continuous flow as indicated in Section 1110.1.

1110.3 Installation

Runoff control shall be by control devices. Control devices shall be protected by strainers.

1110.4 Minimum Number of Roof Drains

Not less than two roof drains shall be installed in roof areas 10,000 square feet (929 m2) or less and not less than four roof drains shall be installed in roofs over 10,000 square feet (929 m2) in area.

Related Code Sections


Section 1110 Storm Drainage, Controlled Flow Roof Drain Systems
The roof of a structure shall be designed for the storage of water where the storm drainage system is engineered for controlled flow. The controlled ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1110 Controlled Flow Roof Drain Systems
8.2 Installation Requirements, System Protection Area Limitations
, check valve, main drain valve, and flow switch for isolation, control, and annunciation of water flow for each individual floor level ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 8 Installation Requirements > 8.2 System Protection Area Limitations
1105.2 Storm Drainage, Roof Drain Flow Rate
The published roof drain flow rate, based on the head of water above the roof drain, shall be used to size the storm drainage system in accordance ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1105 Roof Drains > 1105.2 Roof Drain Flow Rate
1108.3 Storm Drainage, Sizing of Secondary Drains
of the roof drain required for the area served. The flow through the primary system shall not be considered when sizing the secondary roof drain system ...
Plumbing Code 2018 of Kansas > 11 Storm Drainage > 1108 Secondary (Emergency) Roof Drains > 1108.3 Sizing of Secondary Drains
506.5.2 Exhaust Systems, Pollution-Control Units
and the International Building Code . Pollution-control units located indoors shall be listed and labeled for such use. Where enclosed duct systems, as required ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 506 Commercial Kitchen Hood Ventilation System Ducts and Exhaust Equipment > 506.5 Exhaust Equipment > 506.5.2 Pollution-Control Units
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING