1926.760(c) Controlled Decking Zone (CDZ)
JUMP TO FULL CODE CHAPTER
A controlled decking zone may be established in that area of the structure over 15 and up to 30 feet above a lower level where metal decking is initially being installed and forms the leading edge of a work area. In each CDZ, the following shall apply:
Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less.
Access to a CDZ shall be limited to only those employees engaged in leading edge work.
The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent. Examples of acceptable procedures for demarcating CDZ's can be found in Appendix D to this subpart.
Each employee working in a CDZ shall have completed CDZ training in accordance with § 1926.761.
Unsecured decking in a CDZ shall not exceed 3,000 square feet (914.4 m2).
Safety deck attachments shall be performed in the CDZ from the leading edge back to the control line and shall have at least two attachments for each metal decking panel.
Final deck attachments and installation of shear connectors shall not be performed in the CDZ.
Related Code Sections
1926.760(c) Steel Erection, Controlled Decking Zone (CDZ)
A controlled decking zone may be established in that area of the structure over 15 and up to 30 feet above a lower level where metal decking ...
OSHA 1926 Construction > R Steel Erection > 1926.760 Fall Protection > 1926.760(c) Controlled Decking Zone (CDZ)
1926.760(c)(2) Steel Erection,
Access to a CDZ shall be limited to only those employees engaged in leading edge work ...
OSHA 1926 Construction > R Steel Erection > 1926.760 Fall Protection > 1926.760(c) Controlled Decking Zone (CDZ) > 1926.760(c)(2)
1926.760(c)(1) Steel Erection,
Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever ...
OSHA 1926 Construction > R Steel Erection > 1926.760 Fall Protection > 1926.760(c) Controlled Decking Zone (CDZ) > 1926.760(c)(1)
1926.754(c)(2) Steel Erection, Installation of Shear Connectors on Composite Floors, Roofs and Bridge Decks
a controlled decking zone (CDZ), as specified in § 1926.760(c)(8) ...
OSHA 1926 Construction > R Steel Erection > 1926.754 Structural Steel Assembly > 1926.754(c) Walking/Working Surfaces -- Shear Connectors and Other Similar Devices > 1926.754(c)(2) Installation of Shear Connectors on Composite Floors, Roofs and Bridge Decks
1926.754(c) Steel Erection, Walking/Working Surfaces -- Shear Connectors and Other Similar Devices
not be installed from within a controlled decking zone (CDZ), as specified in § 1926.760(c)(8) ...
OSHA 1926 Construction > R Steel Erection > 1926.754 Structural Steel Assembly > 1926.754(c) Walking/Working Surfaces -- Shear Connectors and Other Similar Devices