1910.261(e)(12) Continuous Barking Drums
JUMP TO FULL CODE CHAPTER
When platforms or floors allow access to the sides of the drums, a standard railing shall be constructed around the drums. When two or more drums are arranged side by side, proper walkways with standard handrails shall be provided between each set, in accordance with the requirements of 29 CFR 1910.23, Guarding floor and wall openings and holes.
Whenever it becomes necessary for a workman to go within a drum, the driving mechanism shall be locked and tagged, at the main disconnect switch, in accordance with paragraph (b)(1) of this section.
Sprockets and chains, gears, and trunnions shall have standard guards, in accordance with the requirements of 29 CFR 1910.219, Mechanical power-transmission apparatus.
Related Code Sections
1910.261(e)(12) Special Industries, Continuous Barking Drums
When platforms or floors allow access to the sides of the drums, a standard railing shall be constructed around the drums. When two or more drums ...
OSHA 1910 General Industry > R Special Industries > 1910.261 Pulp, Paper, and Paperboard Mills > 1910.261(e) Preparing Pulpwood > 1910.261(e)(12) Continuous Barking Drums
1910.179(a)(37) Materials Handling and Storage, Drum
The drum is the cylindrical member around which the ropes are wound for raising or lowering the load ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.179 Overhead and Gantry Cranes > 1910.179(a) Definitions Applicable to This Section > 1910.179(a)(37) Drum
1910.180(a)(22) Materials Handling and Storage, Drum
The drum is the cylindrical members around which ropes are wound for raising and lowering the load or boom ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.180 Crawler Locomotive and Truck Cranes > 1910.180(a) Definitions Applicable to This Section > 1910.180(a)(22) Drum
1910.261(e) Special Industries, Preparing Pulpwood
In addition to motor switch, clutch, belt shifter, or other power disconnecting device, intermittent barking drums shall ...
OSHA 1910 General Industry > R Special Industries > 1910.261 Pulp, Paper, and Paperboard Mills > 1910.261(e) Preparing Pulpwood
1910.265(d)(4)(i) Special Industries, Rotary Barkers
Rotary barking devices shall be so guarded as to protect employees from flying chips, bark, or other extraneous material ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(d) Log Handling, Sorting, and Storage > 1910.265(d)(4) Mechanical Barkers > 1910.265(d)(4)(i) Rotary Barkers